INSTALLATION INSTRUCTION
H Track Systems
HT2, HT4, HT6, HT8
FIELD CUTTING TRACK CONTINUED
2. Do not allow bus wires and insulation to protrude from the end and do not cut the wires and
push insulation back into the track.
3. Make a ush cut through track with a ne-toothed hacksaw. File any rough edges or ash.
Brush out any remaining lings.
4. Once the ush cut is made trim 1/4” o the end of the copper bus wire. This will allow sucient clearance for
the end cap for a mating connector. If not performed in this sequence the bus wires will be short and cause faulty contact.
5. When mating to connector already at ceiling level make sure to support connectors at both ends.