 will restore the output to the same state it was at before the meter was
powered down.
 will activate the output at power up.  will deactivate the
output at power up. This parameter is not active when the Setpoint Action is
selected for timed output mode.
SETPOINT OUTPUT POWER-UP STATE
Stops the Timer when the Setpoint output activates () or deactivates
(). Select  if the output should not affect the Timer Run/Stop status.
The Timer Stop condition is cleared when a Timer Reset occurs, or a Time
Start edge is applied on the Timer input.
STOP TIMER
SETPOINT OUTPUT TIME-OUT
SPT ACTION DESCRIPTION OUTPUT ACTIVATES OUTPUT DEACTIVATES

Latched Output Mode
When Time or Count
= Setpoint On value
At Manual Reset
(if
 = )

Timed Output Mode
When Time or Count
= Setpoint On value
After Setpoint
Output Time-Out

On-Off Output Mode
When Time or Count
Setpoint On value
When Time or Count
Setpoint Off value
This parameter is only active if the Setpoint Action is set to Timed Output mode
(). Enter the time duration the Setpoint Output will remain ON once it is
activated. This value is always entered in minutes, seconds, and hundredths of
seconds format. The maximum value is 99 minutes 59.99 seconds.
to
SETPOINT ON
This parameter determines when the Setpoint output will activate. The output
can activate at a programmed Setpoint Value or can be set to activate when the
Timer starts () or stops ().
Selecting  displays a sub-menu where the Setpoint Value is entered. If
the Setpoint is assigned to the Timer, the value is entered in the same display
format as the selected Timer Range.
Automatically resets the Setpoint Assigned display value when the Setpoint
Output activates () or deactivates (). Select  if the output should
not cause a display reset.
TIMER/COUNTER AUTO RESET
Select  to have the Setpoint Output deactivate (reset) when the Setpoint
Assigned display resets. Reset can occur by the RST key or the User Input,
if programmed for that function. Select
 if the Setpoint output should not
reset when the display resets.
SETPOINT OUTPUT RESET WITH DISPLAY RESET




SETPOINT OFF
The Setpoint Off parameter only appears if the Setpoint Action is set to
On-Off Output mode (). In this mode, the Setpoint OFF parameter
determines when the Setpoint Output will deactivate. The output can be
programmed to deactivate at a Setpoint Off Value or can be set to deactivate
when the Timer starts () or stops ().
Selecting
 displays a sub-menu where the Setpoint Off Value is
entered. If the Setpoint is assigned to the Timer, the value is entered in the same
display format as the selected Timer Range.


















5.4 MODULE 4 - SETPOINT OUTPUT PARAMETERS ()
PAR
Setpoint
Output Action
Setpoint
Assignment
Setpoint On
Timer/Counter
Auto Reset
Setpoint O Stop Timer
Setpoint
Output
Time-out
Setpoint
Output Reset
with Display
Reset


      

Setpoint
Output
Power-up
State
 
PARAMETER MENU
Module 4 is the programming module for the Setpoint Output parameters.
Some parameters will not appear depending on the Setpoint Assignment and
Setpoint Output Action selected.
Select the display for Setpoint assignment.
SETPOINT ASSIGNMENT



SETPOINT OUTPUT ACTION
This parameter selects the action of the Setpoint output as shown below.











 to 


 to 



