Operators Manual

Table Of Contents
VP 1340A/VP 1550A Technical Data
wpm_td000314gb.fm 14
3.2 Machine Data
3.3 Sound and Vibration Measurements
The required sound specification, Paragraph 1.7.4.f of 89/392/EEC
Machinery Directive, is:
the guaranteed sound power level (L
WA
) = 108 dB(A).
the sound pressure level at operator’s location (L
pA
):
VP1340A/AW = 95 dB(A), VP1550A/AW = 96 dB(A).
These sound values were determined according to ISO 3744 for the
sound power level (L
WA
) and ISO 6081 for the sound pressure level
(L
pA
) at the operator’s location.
The weighted effective acceleration value, determined according to
EN ISO 5349, is approximately:
VP1340A/AW = 4.50 m/s
2
, VP1550A/AW = 4.50 m/s
2
.
The sound and vibration measurements were obtained with the
machine operating on crushed gravel at nominal engine speed.
VP 1340A/AW
0009031
0009032
VP 1550A/AW
0009027
0009028
Plate
Weight kg (lbs.) VP 1340A: 74 (163)
VP 1340AW: 76 (168)
VP 1550A: 83 (184)
VP 1550AW: 86 (190)
Water Tank Capacity l (qts.) 3.8 (4.0) 7.6 (8.0)
Exciter Speed rpm 5800 ± 100
Exciter Lubrication ml (oz.) 240 (8)
Automatic transmission fluid
Dextron III/Mercon or equivalent
Dimensions mm (in.)
588 (23) x 400 (16) x 911 (35) 588 (23) x 500 (20) x 911 (35)