User manual

EN
SinePower Using the inverter
49
10 Using the inverter
10.1 Switching on the inverter
Set the main switch (fig. 5 3, page 4) of the inverter to the “ON” position.
Set the On/Off switch to “OFF” to switch off.
The inverter performs a self-test.
During the self-test, the built-in speaker emits tones and the LED flashes.
After the self-test is completed successfully, the LED lights up green
(fig. 5 2, page 4).
10.2 Status indications
The LED (fig. 5 2, page 4) shows the operating condition of the inverter.
The inverter switches off if:
the battery voltage drops below 10 V (12 Vg connection) or 20 V (24 Vg
connection),
the battery voltage exceeds 16 V (12 Vg connection) or 32 V (24 Vg
connection),
the inverter overheats.
Display Input voltage
Green, constantly lit Normal mode
Green, slow flash Energy-saving mode
Orange, quick flash Input voltage too high
Orange, slow flash Input voltage too low
Red, double flash Inverter overheated
Red, quick flash Overvoltage
Red, slow flash Undervoltage
Red, constantly lit Overload
Red, slow flash + double flash Fan fault