Operation Manual

EN
CFX35 – CFX65DZ Operation
35
Connecting to a 100240 V AC mains (E.g. in the home or office)
D
The coolers have an integrated multi-voltage power supply with
priority circuit for connecting to an AC voltage source of 100
240 V. The priority circuit automatically switches the cooler to
mains operation, if the device is connected to a 100240 V AC
mains, even if the 12/24 V connection cable is still attached.
Plug the 100 240 V connection cable (fig. 1 3, page 3) into
the device AC voltage socket and connect it to the 100 240 V
AC voltage mains.
6.4 Using the battery monitor
The device is equipped with a multi-level battery monitor that
protects your vehicle battery against excessive discharging when
the device is connected to the on-board 12/24 V supply.
If the cooler is operated when the vehicle ignition is switched off,
the cooler switches off automatically as soon as the supply voltage
falls below a set level. The cooler will switch back on once the
battery has been recharged to the restart voltage level.
A
DANGER! Danger of electrocution!
Never handle plugs and switches with wet hands or if you are
standing on a wet surface.
If you are operating your cooler on board a boat from a mains
connection of 100240 V
~
, you must install a residual current
circuit breaker between the 100240 V
~
mains and the cooler.
Seek advice from a trained technician.
NOTICE! Danger of damage!
When switched off by the battery monitor, the battery will no long-
er be fully charged. Avoid starting repeatedly or operating current
consumers without longer charging phases. Ensure that the bat-
tery is recharged.