36
In “HIGH” mode, the battery monitor responds faster than at the
levels “LOW” and “MED” (see the following table).
The battery monitor mode can be selected as follows:
Switch on the cooler.
Press the “SET” button (fig. 3 4, page 3) three times.
Use the “UP +” (fig. 3 7, page 3) or “DOWN -” (fig. 3 6,
page 3) buttons to select the battery monitor mode.
Digital display will be as follows:
Lo (LOW), Πd (MED), Hi (HIGH)
The selected mode then appears in the display for a few sec-
onds. The display flashes several times before it returns to the
current temperature.
I
Battery monitor mode LOW MED HIGH
Switch-off voltage at 12 V 10.1 V 11.4 V 11.8 V
Restartvoltage at 12 V 11.1 V 12.2 V 12.6 V
Switch-off voltage at 24 V 21.5 V 24.1 V 24.6 V
Restart voltage at 24 V 23.0 V 25.3 V 26.2 V