Installation manual

Installation
CoolAi
r
28
z You can connect the unit to the battery via the lorry's terminal block or
directly. The terminal block is to be preferred for the connection. On
some vehicles, larger consumers connected to the terminal block are
switched off after a short while if the power requirement is too high.
Ask your vehicle manufacturer for the specifications of the terminal
block.
z Pay attention to the connection plan for the device:
a
Caution
Improper installation of the air conditioning roof unit can result in irrepa-
rable damage to the device and put the safety of the user at risk.
The manufacturer will not be held liable for claims if the air conditioning
roof unit is not installed according to this installation manual. That applies
to malfunctions and the safety of the air conditioning roof unit, in particular
to injuries and damage to property.
a
Caution
Before installing the air conditioning roof unit, all connections to the
battery of the vehicle must be disconnected.
Non-observance of this regulation can result in danger of electrocution.
I
Note
After installing the unit, the specified parameters of the unit software must
be checked (see Chapter "Configuration of unit software" on page 32).
No. in fig. 7 on
page 5
Designation
1 Control pad
2 Connection cable
3 Room temperature sensor
4 Earth
5 Klickson (compressor)
6 Compressor
7 Condenser fan
8 Vaporiser fan
9Earth
10 25 A fuse
11 2 A fuse
12 4 A fuse
CA-850S_EBA_Iveco.book Seite 28 Mittwoch, 15. Juni 2011 5:44 17