Installation manual

31
Installation
CoolAi
r
a
Caution
Fit a fuse of 25 amps to the connection to the vehicle's power supply.
a
Caution
The battery must be able to supply the required current and voltage (see
Chapter "Technical data" on page 37).
lveco Stralis AS/AT:You can connect the unit to the battery via the
lorry's terminal block or directly. The terminal block is to be preferred for
the connection. Ask your vehicle manufacturer for the specifications of
the terminal block.
lveco Stralis AS³:You can connect the unit to the battery via the lorry's
terminal block or directly. Here, the connection directly to the battery
should be preferred, as the consumer which is connected to the terminal
block switches off after approx. 10 min if there is a high power require-
ment.
Lay the supply line and connect it to the vehicle (red line to plus, black
line to minus).
Plug in the supply line plug into the socket of the air conditioning roof
unit supply line.
To relieve strain on the supply line, secure it with a cable tie, e.g. to
the cab roof.
6.2.6 Fastening the cover frame
a
Caution
Screw the screws in carefully order not to damage the cover frame.
Fasten the cover frame (fig. 4 on page 4, item 5) the same way as
for the original frame for the sliding roof.
CA-850S_EBA_Iveco.book Seite 31 Mittwoch, 15. Juni 2011 5:44 17