Installation manual

Installation
CoolAi
r
34
6.3.3 Menu level 2: Low voltage cut-off
The battery monitor protects the battery from excessive discharging.
a
Caution
When the the battery monitor switches the device off, the battery only has
part of its charging capacity. Avoid starting repeatedly or operating elec-
trical consumers. Make sure that the battery is recharged. As soon as the
required voltage is available again, the unit can be operated again.
If only the set power supply is available here for the air conditioning roof
unit, the unit is switched off.
Start configuration mode (see Chapter "Starting and ending configu-
ration mode" on page 32).
The first digit of the display (fig. 6 on page 4, item 5) shows the menu
level and the second and third show the parameter which can be set.
Press the
+
button
(
fig. 6 on page 4
, item 6) once to switch to menu
level
2
.
Press the Operating Mode button (fig. 6 on page 4, item 4) to
change the parameter.
The digits in the display flash until the parameter you entered is
confirmed.
Use the +
and
buttons (
fig. 6 on page 4
, item 6 and 7)
to set the val-
ue for low voltage shutdown. The characteristic figures at second and
third place on the digital display represent the voltage (V) at which the
unit is shut down:
Press the Operating Mode button (fig. 6 on page 4, item 4) to
confirm your entry.
The set value is saved and is then used when the unit is restarted.
You are now in menu level 2 again and can use the +
and
buttons to
switch between menu levels.
Characteristic
figure
Low voltage
shutdown
Characteristic
figure
Low voltage
shutdown
1
22,2
6
23,0
2
22,4
7
23,1
3
22,6
8
23,2
4
22,8
9
23,4
5
22,9
10
23,6
CA-850S_EBA_Iveco.book Seite 34 Mittwoch, 15. Juni 2011 5:44 17