BA_CA850S_SP950.book Seite 22 Mittwoch, 2. Mai 2012 5:05 17 Notes on using the manual Please read this instruction manual carefully before starting the product and keep it in a safe place for future reference. If you pass on the product to another person, hand over this operating manual along with it. Contents 1 Notes on using the manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 2 Safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
BA_CA850S_SP950.book Seite 23 Mittwoch, 2. Mai 2012 5:05 17 Safety instructions ✓ This symbol describes the result of an action. fig. 1 5, page 3: This refers to an element in an illustration. In this case, item 5 in figure 1 on page 3. Please observe the following safety instructions. 1.2 Target group The information on the device (operating instructions, handling the device, safety instructions etc.) is intended for the user of the stationary air conditioner.
BA_CA850S_SP950.book Seite 24 Mittwoch, 2. Mai 2012 5:05 17 Safety instructions Do not use the stationary air conditioner near flammable fluids and gases. Switch the stationary air conditioner off before tilting the cab for maintenance. Do not operate the stationary air conditioner if the ambient temperature is below 0 °C. Do not undo the upper cover of the stationary air conditioner in the event of a fire. Use approved extinguishing agents instead. Do not use water to extinguish fires.
BA_CA850S_SP950.book Seite 25 Mittwoch, 2. Mai 2012 5:05 17 Intended use 3 Intended use The stationary air conditioner is used to supply the interior of the driver's cab with cool and dehumidified air. The system is designed for stationary use. It can be used while driving. The stationary air conditioner is not suitable for use in agricultural or construction vehicles. I Note Only install the stationary air conditioner using the manufacturer's assembly kit.
BA_CA850S_SP950.book Seite 26 Mittwoch, 2. Mai 2012 5:05 17 Operation The refrigerant circuit of the stationary air conditioner consists of four main components: Compressor The compressor draws in the R134a refrigerant and compresses it. This raises the pressure and therefore the temperature of the refrigerant. Condenser The built-in condenser works like a cooler or heat exchanger. The air flowing past absorbs the heat and the hot refrigerant gas cools down and becomes liquid.
BA_CA850S_SP950.book Seite 27 Mittwoch, 2. Mai 2012 5:05 17 Operation 5.2 Control panel The following control and display elements are available on the control panel for operating the system: No. in fig. 2, page 3 Meaning 1 ON/OFF button 2 Fault LED (red): The LED indicates system malfunctions. 3 Compressor LED (yellow): The LED lights up when the compressor is operating. 4 Mode button: Use the Mode button to switch between operating modes 1, 2, 3 or Automatic and the Timer function.
BA_CA850S_SP950.book Seite 28 Mittwoch, 2. Mai 2012 5:05 17 Using the stationary air conditioner 5.3 Remote control The remote control is equipped with the following control elements for operating the system: No. in fig. 3, page 4 1 STANDBY button The system can be switched between active and standby modes. 2 Temperature – button: The temperature – button decreases the temperature by 1 °C or the timer running time by 10 minutes.
BA_CA850S_SP950.book Seite 29 Mittwoch, 2. Mai 2012 5:05 17 Using the stationary air conditioner 6.1 Tip for improved use I Note CA850S and SP950 are designed as air conditioning roof units for relaxing rest periods. They can be used while driving, do not however replace the engine-powered vehicle air conditioning system.
BA_CA850S_SP950.book Seite 30 Mittwoch, 2. Mai 2012 5:05 17 Using the stationary air conditioner 6.2 a I Switching on the stationary air conditioner Caution Never close all of the air nozzles of the stationary air conditioner simultaneously. The device would ice up inside. Note The first time the stationary air conditioner is used, there may be a slight smell. This is normal and soon goes away. ➤ With the system switched off, press the ON/OFF button (fig. 2 1, page 3).
BA_CA850S_SP950.book Seite 31 Mittwoch, 2. Mai 2012 5:05 17 Using the stationary air conditioner 6.3 Selecting the temperature You can select temperatures between 17 °C and 30 °C. ➤ Press + or – (fig. 2 6/7, page 3) on the control panel or + or – (fig. 3 2/3, page 4) on the remote control to set the temperature in 1 °C increments. ✓ The digital display (fig. 2 5, page 3) shows the operating mode and the selected temperature in °C.
BA_CA850S_SP950.book Seite 32 Mittwoch, 2. Mai 2012 5:05 17 Using the stationary air conditioner 6.5 Extracting condensation (SP950 only) The condensated water which accumulates due to the way the system works is automatically extracted at intervals during operation. You can pump out the condensated water manually when necessary: ➤ Switch off the system. ➤ Press and hold the Operating mode (fig. 2 4, page 3) and – (fig. 2 7, page 3) buttons simultaneously. ➤ In addition, press the ON/OFF button (fig.
BA_CA850S_SP950.book Seite 33 Mittwoch, 2. Mai 2012 5:05 17 Using the stationary air conditioner I Note You can only use the remote control to switch the stationary air conditioner in and out of standby mode. SP950 ➤ Switching to standby mode: With the unit switched on, briefly press the ON/OFF (fig. 2 1, page 3) button or the “ ” (fig. 3 1, page 4) button on the remote control. ✓ The digital display goes out, only the green power LED lights up. ✓ The compressor and the fan switch off.
BA_CA850S_SP950.book Seite 34 Mittwoch, 2. Mai 2012 5:05 17 Display messages 7 Display messages I Note When you start the vehicle or switch on several consumers at once, the display text LO may briefly appear. 7.1 Control panel warnings The system control unit has various functions for protecting the device and the battery. If one of these protective functions has been triggered, this is shown by the following codes on the display.
BA_CA850S_SP950.book Seite 35 Mittwoch, 2. Mai 2012 5:05 17 Display messages 7.2 Control panel fault messages The “Fault” LED (fig. 2 2, page 3) lights up if there is a fault with the stationary air conditioner. The type of error is shown on the display by the following error codes: Display text Description Cause FO1 The compressor does not work. FO2 The system cannot determine the current temperature. FO3 Compressor overload or ➤ Switch off the system.
BA_CA850S_SP950.book Seite 36 Mittwoch, 2. Mai 2012 5:05 17 Maintenance and care 8 Maintenance and care Please observe the following tips for the maintenance and care of your stationary air conditioner. a Caution Do not use abrasive cleaning agents or hard objects during cleaning as these can damage the unit. Do not clean the stationary air conditioner with a high-pressure cleaner. Exposure to water can damage the stationary air conditioner.
BA_CA850S_SP950.book Seite 37 Mittwoch, 2. Mai 2012 5:05 17 Disposal 10 Disposal ➤ Place the packaging material in the appropriate recycling waste bins wherever possible. M If you wish to finally dispose of the product, ask your local recycling centre or specialist dealer for details about how to do this in accordance with the applicable disposal regulations. 10.1 Disposing of remote control batteries B Protect the environment! Do not dispose of any batteries with general household waste.
BA_CA850S_SP950.book Seite 38 Mittwoch, 2. Mai 2012 5:05 17 Technical data 11 Technical data Stationary air conditioner CoolAir CA850S Cooling capacity: 850 W Voltage: 24 V DC (20 V DC – 30 V DC) Current consumption: 12 – 22 A Operating temperature range: 0 – 43 °C Low voltage shutdown: Configurable (See installation manual) Dimensions (L x W x H): 635 mm x 830 mm x (165 – 187) mm (Height vehicle-specific) Weight: approx.