Instruction manual

EN
Installing and connecting the refrigerator CR50, CR 65, CR80, CR110, CR140
42
7.4 Connecting the refrigerator
Connect the refrigerator to DC power
The refrigerators can be operated with 12 Vg or with 24 Vg.
e
Warning!
To avoid voltage drops and loss of performance, keep the cable as
short as possible and avoid joins.
For this reason avoid additional switches, plugs or multi-way
adapters.
Determine the required cross section of the cable in relation to the cable
length according to fig. e, page 9.
Key for fig. e, page 9
e
Warning!
Make sure that the polarity is correct.
Before starting up the appliance for the first time, check whether the
operating voltage and the battery voltage match (see type plate).
Connect the refrigerator
as directly as possible to the poles of the battery or
to a 12 or 24 Vg socket.
Fit a fuse in the positive wire of 15 A (for 12 V) or 7.5 A (for 24 V)
(fig. f 1, page 9).
Connect the red cable (fig. f rt, page 9) to the positive terminal of the
battery.
Connect the black cable (fig. f sw, page 9) to the negative terminal of
the battery.
e
Warning!
Disconnect the refrigerator and other electric loads from the battery
before connecting the battery to a quick charging device.
Overvoltage can damage the appliance electronics.
Co-ordinate axis Explanation Unit
l Cable length m
Cable cross section mm²
_cr-kuehlschraenke.book Seite 42 Montag, 27. Februar 2012 12:46 12