Instruction manual

EN
CR50, CR 65, CR80, CR110, CR140 Installing and connecting the refrigerator
43
For safety reasons the refrigerator is equipped with an electronic system to
prevent the polarity being reversed. This protects the refrigerator against re-
versed polarity when connecting to a battery and against short circuiting. To
protect the battery, the refrigerator switches off automatically if the voltage is
insufficient (see table below).
Connecting the refrigerator to AC power (accessory)
I
Note
The CR140 and all US versions are available in DC/AC version
only. Without using a rectifier, these refrigerators can be operated
using a 110-240 V~ current source, in addition to a 12 or 24 Vg
current source.
You can connect the refrigerator to AC power if you use a rectifier
(accessory):
110 - 240 V: MPS-35
a
Caution – Danger of electrocution
Never handle plugs and switches with wet hands or if you are
standing on a wet surface.
e
Warning!
If you are operating your refrigerator on board a boat with a mains
connection of 230-V from the land, you must install a residual cur-
rent circuit breaker between the 230V mains supply and the refrig-
erator.
Seek advice from a trained technician.
I
Note
Always connect the refrigerator to the rectifier. Otherwise the prior-
ity circuit for the refrigerator will be disabled.
The priority circuit reduces the load on a connected battery by the
rectifier always switching to mains operation if AC power is con-
nected.
12 V 24 V
Cut-off voltage
10.4 V 22.8 V
Cut-in voltage
11.7 V 24.2 V
_cr-kuehlschraenke.book Seite 43 Montag, 27. Februar 2012 12:46 12