ELECTRICAL REQUIREMENTS
The Danfoss compressor is powered by an internal 12V DC brushless motor. The
D
C brushless motor operates by a continuous “loop” of information passing
between the electronic module and the compressor. Because this operation
requires a “clean” and uninterrupted supply of direct current power, it is
recommended that the refrigerator have a direct connection to the battery.
Wiring it into the fusebox, terminal block, buss bar, or another electrical circuit,
may subject the supply voltage to electrical “noise”, or interference, which may
disrupt the informational loop and render the electronic module inoperative.
Best practice is to wire the unit directly to the battery with an inline fuse on the
positive (+) terminal.
The CR Series refrigerator should be wired on its own circuit. There should be no
other electrical loads on the same circuit. Although 10 amp protection is
sufficient,
15 amp is preferable.
The appliance must be wired and grounded in accordance with ABYC guidelines.
Refer to the guidelines on page 5.
Failure to provide a sufficient wire size will result in an unacceptable voltage drop
and inability of the refrigerator to operate.