User’s Manual—Read before using this equipment
PROBLEM: Inverter Shut Down – Fault LED Lit
Reason Solution
Equipment being operated draws too
much power.
Use a higher wattage inverter or do not
use this equipment.
PROBLEM: Continuous Buzzing Sound
Reason Solution
Input voltage below 10.5 Volts Keep input voltage above 10.5 Volts
Poor or weak battery condition. Recharge or replace battery.
Poor or loose cable connection Inspect terminals and tighten all con-
nections.
Inadequate power being delivered to
the inverter or excessive voltage drop.
Use heavier gauge DC cable.
Keep cable length as short as
possible.