Instructions

1-2 Technical features
Power supply voltage 230 V a.c. +/- 10%
Frequency 50-60 Hz
Protection rating IP20
Output type
Operating temperature From 0 °C to +50 °C
Storage temperature from -10°C to +65°C
Absorption/Self-consumption 6.5 VA single channel / 7.8 VA twin channel
at terminals
1...6mm
²
CE standards LVD/EMC EN60730-2-7
Languages available in menu
Italian, English, German, French, Spanish,
Swedish, Portuguese, Dutch, Russian,
Polish, Greek
Backup in case of power
failure
6 years from first switch on, guaranteed
by lithium battery
Nominal pulse voltage 4kV
Time tolerance
3000W 3000W 1100W
900W
(125 μF)
7W ÷ 23W
(max. 23 lamps)
Channel 1/Channel 2 OFF/ Channel deactivated
Manual forcing of channel
ON / Channel active
Random programs Cyclic programs
Holidays icon Keyboard lock
GPS or DCF77 signal
reception indication
Scroll up
Program no. Selected
P01-P64
Scroll down
The striped bar on the display also shows:
Progress status, see Fig.2 on page 17 (e.g. cancelling see chapt. 3-6).
Hour display, see Fig.3 on page 17.
The display shows alternately (for a few seconds) the date and the time and
the programs or forcings set.
i
i
Installation
DIN- back panel (with optional KIT)
Software
Class A
Insulation class Class II
Pollution rating Normal
Standard Time (summer)
Daylight Saving Time (winter)
1-3 Display (see Fig. 1 on page 17)
+/ 0.5 sec/day at 25°C
19
Potential-free relay with changeover contact;
N.O. Contact = 16(10)A / 250V~ (limited
current with Resistance for Zero Crossing of
high value);
N.C. contact = 16(2)A / 250V~
Cross-section of cables
EN
Maximum pilotable power