Manual and Installation Guide

Introduction
Thank you for purchasing the Environ™ Flex Roll System. This manual contains IMPORTANT information
regarding the safe use and installation of your Environ™ Flex Roll System. Please read through the entire
manual carefully before you install or operate your oor heating system.
Important Information
Environ™ Flex Rolls are designed for installation directly under laminate/
oating wood and engineered wood, installed on top of an underlayment.
Environ™ Flex Rolls are NOT designed for installation under ceramic tile,
natural stone or other similar hard oor coverings; and MAY NOT be installed
under nailed hardwood ooring. WarmlyYours sells products to heat these
ooring surfaces Contact us at: info@warmlyyours.com, or (800) 875-5285
for more information on other oor heating system options available.
Environ™ Flex Rolls should be separated from other heat sources such as
luminaries and chimneys.
The minimum distance between adjacent runs should be at a minimum of 1.5”
(40 mm).
Do not install the Environ™ Flex Rolls at an ambient temperature below 5ºF
(-15ºC).
Environ™ Flex Rolls should not extend beyond the room or area in which it
originates, as per the custom installation SmartPlan™.
The Environ™ Flex Rolls must be spaced from the walls a minimum distance
of 3” (76 mm).
Certain underlayment types and thicknesses with laminates/oating wood are
NOT compatible with Environ™ Flex Rolls (see page 5). DO NOT PLACE
EXCESSIVELY HEAVY FURNITURE on your heated oor.
Environ™ Flex Rolls must not be installed under cabinets or furniture that will
be permanently installed and attached to the oor. Built-in cabinets and other
furniture with solid bases must not be placed over the rolls.
Environ™ Flex Rolls is not for installation in walls.
We want your installation to be trouble-free. If you are confronted with
a problem you cannot solve, please do not hesitate to contact us at:
info@warmlyyours.com, or call us any time, any day at (800) 875-5285.
Environ™ Flex Rolls should NOT be installed on top of other in-oor radiant
heating systems (for example hydronic or in-slab systems) UNLESS the
other system is permanently disconnected in such a way that it cannot be
inadvertently switched on while the Environ™ Flex Rolls are also in use.
The Environ™ Flex Rolls may NOT be installed on oors where radiant ceiling
heating rolls are in use in the room directly below where the Environ™ Flex
Rolls are installed.
Environ™ Flex Rolls must not be installed in thinset cement, or in direct contact
with a cement or concrete suboor or slab. There must be an underlayment
under Environ™ Flex Rolls.
Indicate which branch circuits supply the power to the Environ™ Flex Rolls and
retain the UL labels for each heating roll in a convenient location, i.e. taped to
the circuit breaker box, for reference by the electrical inspector or home owner.
Leave one UL label attached to the Environ™ Flex Rolls. Attach warning label
in a convenient location to show the room location where Environ™ Flex is
installed.
Use only listed conduit, ttings, and/or other listed components.
In Canada, the installation should be done according to the provisions of the
Canadian Electrical Code, Part 1, Section 62.
When used in wet locations, the installation should be in accordance with the
National Electric Code, NFPA-70 and CAN/CSA-C22.1, Canadian Electrical
Code, Part I (CEC) and that nal acceptance is to be made in the eld by the
Authority Having Jurisdiction (AHJ).
Environ™ Flex Rolls should be connected to a CLASS-A Ground Fault Circuit
Interrupter (GFCI). Some local electrical codes may require that a qualied
electrician connect the system.