Manual and Installation Guide
Controlling Your System
WarmlyYours recommends a Class-A GFCI, UL/CSA/ETL or similar NRTL listed thermostat to control the Environ™ Flex
Rolls. A programmable thermostat will allow you to set your oor warm-up time and will provide you increased energy
efciency, by programming your wake up, away, bedtime, and vacation settings.
Most wood laminate manufacturers specify that their oors should not be subjected to temperatures in excess of 85ºF
(29ºC). The only reliable way to achieve this is to install a temperature sensor directly under the Environ™ Flex Rolls.
Check with your laminate manufacturer to see their recommendations for installing electric radiant heat under their oors.
Any of the thermostats from the WarmlyYours nSpiration Series can be set to the temperature recommended by the
laminate manufacturer.
Professional Electric Installation
Attention: Some local codes require that a licensed electrician complete the nal connection of the
oor heating system.
The installation of electrical systems presents a risk of re and electrical
shock, which may result in personal injury. Caution should always be
taken to guard against these risks. A qualied electrician should connect
Environ™ Flex Rolls to the thermostat and/or to the electrical supply circuit.
All such connections MUST be in accordance with the National Electric
Code, Canadian Electric Code, and all local codes.
WarmlyYours strongly suggests a dedicated circuit for each system. A non-
dedicated circuit can cause nuisance tripping of the GFCI built into the
thermostat.
Items Required For System Installation
• The customized installation SmartPlan™ (oor plan layout)
• Ground Fault Circuit Interrupter (GFCI)
• Digital Ohm Meter (multi-meter)
• 4” x 4” extra-deep box with a single gang plaster ring
• Junction box for systems requiring more than 3 rolls
• Wire and appropriate-sized, non-GFCI breaker for supplying voltage
• Electrical conduit
• Adhesive tape
• Aluminum tape strips
3