Ember Infrared Heating Panels Installation Manual Free Design Service • 24/7 Installation Support • (800) 875-5285 • www.WarmlyYours.
Table of Contents Sections: page 1. General Product Information .......................................................................................................... 1 1.1. General Information About Infrared Radiant Panels ......................................................................... 1 1.2. General Information About Ember Panels ....................................................................................... 1 1.3. Various Applications And Models ...................................
General Product Information Section 1 Thank you for purchasing an infrared heating panel produced by INFRAPOWER MANUFACTURING LTD., sold by WARMLYYOURS RADIANT HEATING. THIS VERSION OF THE INSTRUCTION MANUAL HAS BEEN TRANSLATED FROM THE ORIGINAL GERMAN VERSION APPROVED BY TÜV RHEINLAND GERMANY. WE DO NOT TAKE ANY RESPONSIBILITY FOR THE TRANSLATED VERSION. PLEASE ASK YOUR DEALER FOR THE ORIGINAL GERMAN VERSION. EMBER heating panels operate on electricity.
General Product Information Section 1 1.3. Various Applications and Models 1.3.1. Ceiling Panels In order to heat a room optimally, EMBER panels should be attached to the ceiling. This optimizes the radiation. Plus, it saves space. EMBER panels are light enough to be integrated into existing ceiling systems. Please note the necessary details for instructions described in Section 3.1. 1.3.2. Wall Panels EMBER wall panels can be optimally used as a supplementary or primary heating system.
Safety Notes Before First Use Section 2 2.1. General Safety Instructions • All EMBER heating panels are only suitable for use as a heating element. Any improper use can present a significant danger to people, animals and the environment.
Instructions for Installation Section 3 3.1 Instructions for Mounting EMBER panels must be mounted with the supplied original mounting hardware (aluminum profiles at the back of the panels and screws included). For panels that are used without the original mounting hardware, the warranty, liability and consequential damages are void. EMBER panels must only be used in the manufacturer-related frames. For panels that are used without the original frame, the warranty, liability and damages are void. 3.1.2.
Instructions for Installation Section 3 3.1.3. General Information on Positioning With infrared radiation, improper positioning can result in certain areas of space in a room experiencing a “shadow” effect. Optimal positioning can avoid shadow effects. For detailed information about the optimal positioning, please consult your dealer where you purchased the EMBER panel. Good Positioning Bad Positioning Good Positioning Bad Positioning 3.2. Instructions for First Use • Note that Section 3.1.
Instructions for Installation Section 3 3.3. Instructions for Regular Use • Do not place any clothing or other similar items on the heating element (FIRE DANGER). A sign is mounted on the front of the panel and must not be removed. • When heating up or cooling down, the expansion and contraction of the heating panels can cause minimal noise. This is normal. • The heater is very hot in use. Contact could lead to serious burns.
Technical Details Section 4 4. Technical Details The following information provides general information applicable to the EMBER radiant panel line. Please find additional information about performance, size and surface temperature on the sticker located on the back of the panels.
Environmental Protection Section 5 5. Environmental Protection Please note the following guidelines for disposing of packaging materials: • Packaging material made of cardboard can be recycled. • Keep plastic foils or packaging out of the hands of children. Please recycle the protective film properly. • The heater, or parts thereof, may not be disposed with normal household waste, but must be taken to a collection point for recycling of electronic and electric devices.
Declaration of Conformity Section 6 6. Declaration of Conformity We hereby declare that the heating panel to which this declaration relates, is compliant with the following guidelines and standards: UL 499:2005 R3.11 EN60335-1 CAN/CSA C22.2 No. 60335-1-11 EN60335-2-30 CAN/CSA E60335-2-30:2001 EN50366 6.1. Transport and Delivery Each individual heater element is, after final testing, packaged securely in suitable boxes and shipped.
Occurrence of an Error Section 7 7. Occurrence of an Error Dear Customer, Thank you for choosing a product from WARMLYYOURS RADIANT HEATING. Should there be an issue with your device, we ask you to first contact the dealer from which you purchased the device. Should the problem not be solved in this way, please send your device back to the dealer and enclose the following warranty card. • WARMLYYOURS provides on all EMBER radiant panels a 5-year warranty, from the date of purchase.
Section 8 Warranty Card EMBER® Warranty Information Please complete and return the Warranty Card (online or you may send/fax this form) www.warmlyyours.com/en-US/radiant-panel-heating/warranty/register or call (800) 875-5285 to register via phone or Fax us at (800) 408-1100 HOMEOWNER INFORMATION Name Phone Address Email City State Postal/Zip Fax Product Serial Number: INSTALLER INFORMATION Company Name Phone Address Email City State Postal/Zip Fax Product Serial Number: WarmlyYours.com Inc.