Introduction
This manual contains IMPORTANT information regarding the safe use and installation of
your foil heaters. Please read through the entire manual carefully before you install or
use the product.
Items required
Before installing your new Warmup® Foil heater, be sure that you have the following
additional parts:
The customized installation plan (or layout)
A Warmup® Thermostat
Digital ohm meter (multi-meter)
30mA RCD
Electrical Junction box
Electrical conduit
Insulation material
Warmup® Foil mats must be fitted directly on top of the Insulation, and directly under the
wood laminate flooring.
Before installation always check the subfloor has adequate thermal insulation. This is
particularly important where the foil heaters will be used as a primary heat source. A heat
loss calculation MUST be carried out to ensure that the product will provide enough heat
for your room.
See page 7 for information on suitable insulation materials.
2
Calculate the area of the floor to be heated. This is the total floor area minus any
permanent fixtures.
Length x width = m
2
Select the heating mat or combination of mats closest in size to the area you want to heat.
See page 6 for the full range of heater sizes. .
Remember
Heaters cannot overlap
Heaters must be connected in parallel
A single thermostat can control up to handle loads up to 16 Amps.
How to select the correct heater or heater combination