Heater Information
5
Construction:
The Warmup
®
Foil system is constructed using dual core fluoropolymer insulated heating
cables sandwiched between two layers of specially reinforced aluminium foil.
The aluminium foil along with the uniform spacing of the heating elements ensures even heat
distribution. The heating elements are connected to the power supply cable, which exits the
mat from one corner.
About the Product
The Foil Heaters must not be installed in thinset cement or in direct contact with a
cement or concrete slab. The heater must be installed on top of a suitable soft Insulation
material . The Warmup® Insulation board may be used if additional levels of insulation are
required but a soft underlay will need to be installed on top of the board.
If a vapour barrier is to be installed it should be laid below the insulation and not on top of
the heater.
Technical Specication:
Voltage
230 Vac - 50 Hz
Standard Wattage
80W /m
2
and 140W /m
2
Mat Width
500mm
Heating Cable Spacing
50mm
Cold Lead length
3m
IP Rating
IPX7
Tested in accordance with
EN60335-1-2002, EN60335-2-96:2002 & EN62233:2008
1. Wood/ Laminate flooring
2. Warmup® Foil Heater
3. Soft Insulation Material
4. Subfloor
1. Wood/ Laminate flooring
2. Warmup® Foil Heater
3. Underlay
4. Warmup® Insulation Board
5. Subfloor