Operating instructions

SoftCare Evo - Type SE10 3-17
CAUTION
Low-pressure water dis-
tribution
1 = Hot water
2 = Winter water control
3 = Hot water + Winter
water control
Fig. 3-17: Hot water supply and
winter water control
Chapter 3 - Structure and function
3.3.1. Fluid system
A modification of the water and air pressure set-
tings may cause damage to the system and/or
vehicle and/or a deterioration of the washing re-
sult.
Change settings only in agreement with
WashTec.
The low-pressure water distribution (see figure 3-18)
distributes the fresh and process water through the
outlets to the individual spray systems. It has a
modular structure and varies depending on the con-
figuration of the system.
The sequence of the outlets at the process water
side (A) is fixed. The sequence of the outlets at the
fresh water side (B) is variable. At systems without
process water system, fresh water is supplied
through the process water inlet.
The water flow pressure can be read off the water
pressure gauges when the spray system is switched
on. The water flow pressure can be adjusted at the
pressure regulator (see chapter 6).
For systems with hot water supply and/or winter wa-
ter control: The water distribution is located in the
upper left corner of the media cabinet.
The illustration on the next page shows all possible
configurations.