Operating instructions

SoftCare Evo - Type SE10 3-21
CAUTION
Heater and freeze pro-
tection device
Fig. 3-22: Heater
Chapter 3 - Structure and function
The heater (1+2) in the media cabinet guarantees a
safe operation during low temperatures. A tempera-
ture sensor controls the temperature in the cabinet. If
the temperature drops 2° below the temperature set-
point the heater is switched on automatically.
Temperature setting with service program menu
0371 (see chapter 9.6).
The freeze protection device provides protection
from frost damage to the water system for roll-over
car wash systems that are installed outdoors or
which are not protected from frost. A temperature
sensor controls the temperature. If the temperature
drops 2° below the temperature set-point, the execut-
ing wash program will first be finished. Afterwards
the freeze protection program will be started to drain
all spray systems.
Temperature setting with service program menu
0370 (see chapter 9.6).
The system cannot execute a wash program while
the freeze protection program is running.
Frost damage when the system is switched off
and/or not installed correctly.
Water supply has to be installed in a freeze pro-
tected room. All supply lines have to be installed
frost-proof.
Leave main switch and compressed air turned on
at the risk of frost. Release emergency-off button.
2