Chapter 6 – Settings and checking
6. Settings and checking
Adjustments at a system which is switched on
may cause serious accidents.
Pay unconditional attention to the safety instruc-
tions in chapter 2.
6.1. Adjusting the compressed air
The filter pressure regulator cleans the compressed
air from destructive particles and regulates the main
pressure.
Set-value main pressure: approx. 6 bar.
The ball valve (7) is used to control the supply of
compressed air. Always close the ball valve to sepa-
rate the system from the existing compressed air
supply (e.g. for maintenance work).
The compressed air is adjusted at the regulator
knob (3).
)
Release the regulator by pulling up the regula-
tor knob.
)
Set the required pressure by turning the regu-
lator knob to the right or left. The adjustment
range is between 0.6 and 10 bars.
)
Secure the regulator by pushing the regulator
knob back down again.
The compressed air may contain condensation water
which settles in the condensation container (4). The
draining is carried out automatically by the drain
valve (6).
Only oil-free compressed air is permitted.
In most countries mandatory.