Operating instructions

SoftCare Evo - Type SE10 6-3
Fig. 6-2: Adjusting air pressure
Chapter 6 – Settings and checking
The air pressure is adjusted by the control knob.
)
Release the regulator by pulling the knob
downwards.
)
Set the required pressure by turning the knob
to the right or to the left.
)
Secure the regulator by pushing the knob up-
wards.
Reading and setting of the air pressure for foam
spray systems is only possible when the spray
system is switched on.
)
Switch on the desired foam spray arch by us-
ing the menu 038 in the service program (see
chapter 9.6).
)
Readjust air pressure.
)
Check the result.
The best cleaning result is achieved with liquid and
fine blowy foam which flows down the vehicle.
)
Switch off the foam spray arch by using the
menu 038 in the service program (see chapter
9.6).
The optimum air pressure depends essentially
from the chemical cleaning agents used in the
system and has been optimally adjusted by
WashTec Service during initial commissioning of
the system.
A modification of the settings may cause a dete-
rioration of the washing or preservation result.
Change settings only in agreement with
WashTec.
NOTICE
NOTICE