Operating instructions

SoftCare Evo - Type SE10 6-9
Water flow pressure for
process water- / fresh
water supply and for
fresh water supply at
systems without foam
system
Water flow pressure for
fresh water supply at
systems with foam sys-
tem
Chapter 6 - Operation and settings
)
Switch on a spray arch which is supplied with
process water, e.g. pre-rinsing, by using the
menu 038 in the service program (see chapter
9.6. “Service program – program menus”).
)
Read off the flowing pressure at the pressure
gauge.
)
Readjust the setting if necessary at the pres-
sure regulator.
Set value with spray system is switched on: 3 bar.
)
Switch off the spray arch by using the menu
038 in the service program.
)
Regulate the air pressure at one foam reactor
(e.g. foam wax) to zero.
Important: Memorize setting.
The flow pressure may be adulterated when air pres-
sure is applied on the foam reactor (higher flow pres-
sure).
)
Switch on the spray arch which is associated
to the selected foam reactor, e.g. foam wax,
by using the service program.
)
Read off the flowing pressure for the fresh
water supply at the pressure gauge.
)
Readjust the setting if necessary at the pres-
sure regulator.
Set value with spray system switched on: 3 bar
)
Switch off the spray arch by using the menu
038 in the service program.
)
Adjust the air pressure at the foam reactor to
the previously set value.