Operating instructions

SoftCare Evo - Type SE10 8-1
Chapter 8 - Error messages
8. Error messages
The error messages will be shown in the display of
the operating unit according to the pattern shown
below:
Module
Part
name
Failure
No.
Type of
failure Cause of failure
DB1 S15 025 No travel
pulses
Pulse counter
DD1 B4 039 Short circuit
transmitter
Light barrier front
CHK 061 Safety strip
initiated
Emergency-off
The module abbreviation shows the module where
the failure has been occurred, for example DB1 =
roof brush. The table on page 8-3 shows the as-
signment of the abbreviations to the modules.
The part name indicates the part, e.g. S15 = switch
no. 15.
The failure number is a consecutive number which is
associated to the type of failure.
The type of failure is an indication for the failure, e.g.
short circuit at the transmitter of a light barrier. The
cause of failure indicates the failure source, e.g. light
barrier front. The tables on page 8-5 to 8-10 show
the different type of failures and causes of failures.