Owner manual

Watlow EZ-ZONE
®
PM Integrated Controller 115 Chapter 8 Factory Page
Factory Page
Dis-
play
Parameter Name
Description
Range Default
Modbus
Relative Ad-
dress
CIP
Class
Instance
Attribute
hex (dec)
Pro-
fibus
Index
Param-
eter ID
Data
Type
&
Read/
Write
[rLoC]
[rLoC]
Security Setting
Read Lock
Set the read security
clearance level. The
user can access the
selected level and all
lower levels.
If the Set Lockout Secu-
rity level is higher than
the Read Lockout Secu-
rity, the Read Loc
kout
Security level takes
priority.
1 to 5 5
Instance 1
Map 1 Map 2
1848 2318
0x67 (103)
1
0x0A (10)
- - - - 3010
uint
RWE
[SLoC]
[SLoC]
Security Setting
Write Security
Set the write security
clearance level. The
user can access the
selected level and all
lower levels.
If the Set Lockout Secu-
rity level is higher than
the Read Lockout Secu-
rity, the Read Locko
ut
Security level takes
priority.
0 to 5 5
Instance 1
Map 1 Map 2
1844 2314
0x67 (103)
1
0x0B (11)
- - - - 3011
uint
RWE
[loC;l]
[LoC.L]
Security Setting
Locked Access Level
Determines user level
menu visibility when
Password Enable is set
to on. See Features sec-
tion under Password
Security.
1 to 5
5
- - - - - - - - - - - - 3016
uint
RWE
[roll]
[roLL]
Security Setting
Rolling Password
When power is cycled
a new Public Key will
be displayed and User
Password changes.
[`off] Off
[``on] On
Off
- - - - - - - - - - - - 3019
uint
RWE
[pas;u]
[PAS.u]
Security Setting
User Password
Used to acquire access
to menus made avail-
able through the Locked
Access Level setting.
10 to 999
63
- - - - - - - - - - - - 3017
uint
RWE
[pas;a]
[PAS.A]
Security Setting
Administrator Pass-
word
Used to acquire full ac-
cess to all menus includ-
ing disabling or chang-
ing passwords.
10 to 999
156
- - - - - - - - - - - - 3018
uint
RWE
Note:
Some values will be rounded off to fit in the four-character display. Full values can be read
with other interfaces.
If there is only one instance of a menu, no submenus will appear.
R: Read
W: Write
E: EEPROM
S: User
Set