Owner manual

Watlow EZ-ZONE
®
PM Integrated Controller 63 Chapter 5 Operations Page
Operations Page
Dis-
play
Parameter name
Description
Range Default
Modbus
Relative Ad-
dress
CIP
Class
Instance
Attribute
hex (dec)
Probus
Index
Param-
eter ID
Data
Type
& Read/
Write
[`C;Lo]
[ C.Lo]
Current (1)
Current Low Set Point
Set the current value
that will trigger a low
heater error state.
-1,999.000 to 9,999.000 0.0 Instance 1
Map 1 Map 2
1136 1376
0x73 (115)
1
9
- - - - 15009 float
RWES
[`CU;r]
[ CU.r]
RMS Current (1)
Current Read
View the RMS current
value monitored by the
current transformer.
0 to 9,999.00 - - - - Instance 1
Map 1 Map 2
1132 1372
0x73 (115)
1
7
- - - - 15007 float
R
[`C;Er]
[ C.Er]
Current (1)
Current Error
View the most recent
load status.
[nonE] None (61)
[Shrt] Shorted (127)
[open] Open (65)
None Instance 1
Map 1 Map 2
1160 1400
0x73 (115)
1
2
- - - - 15002 uint
R
[`h;Er]
[ h.Er]
Current (1)
Heater Error
Determine if load cur-
rent flow is within
the High and Low Set
Points.
[nonE] None (61)
[high] High (37)
[Low] Low (53)
None Instance 1
Map 1 Map 2
1124 1364
0x73 (115)
1
3
- - - - 15003 uint
R
No
Dis-
play
Current (1)
Error Status
View the cause of the
most recent load fault
[nonE] None (61)
[fail] Fail (32)
- - - - Instance 1
Map 1 Map 2
1160 1400
0x73 (115)
1
21
- - - - 15021 uint
R
[MAt]
[oPEr]
Math Menu
[`Su;A]
[ Sv.A]
Math (1)
Source Value A
View the value of Source
A or Linearization 1.
-1,999.000 to 9,999.000°F
or units
-1,128.000 to 5,537.000°C
0.0 Instance 1
Map 1 Map 2
- - - - 3030
0x7D
(125)
1
0x10 (16)
- - - - 25016 float
RWES
[`Su;b]
[ Sv.b]
Math (1)
Source Value B
View the value of Source
B or Linearization 2.
-1,999.000 to 9,999.000°F
or units
-1,128.000 to 5,537.000°C
0.0 Instance 1
Map 1 Map 2
- - - - 3032
0x7D
(125)
1
0x11 (17)
- - - - 25017 float
RWES
[`Su;E]
[ Su.E]
Math (1)
Source Value E
Disables Process/Devia-
tion scale when on.
[`off] Off (62)
[``on] On (63)
0 Instance 1
Map 1 Map 2
- - - - 3038
0x7D
(125)
1
0x14 (20)
- - - - 25020 uint
RWES
[oFSt]
[oFSt]
Math (1)
Offset
Set an offset to be ap-
plied to this function's
output.
-1,999.000 to 9,999.000°F
or units
-1,128.000 to 5,537.000°C
0.0 Instance 1
Map 1 Map 2
- - - - 3044
0x7D
(125)
1
0x17 (23)
- - - - 25023 float
RWES
[``o;u]
[ o.v]
Math (1)
Output Value
View the value of this
function's output.
-1,999.000 to 9,999.000°F
or units
-1,128.000 to 5,537.000°C
0.0 Instance 1
Map 1 Map 2
- - - - 3042
0x7D
(125)
1
0x16 (22)
- - - - 25022 float
RWES
Note:
Some values will be rounded off to fit in the four-character display. Full values can
be read with other interfaces.
R: Read
W: Write
E: EEPROM
S: User
Set