Owner manual

Watlow EZ-ZONE
®
PM Integrated Controller 96 Chapter 6 Setup Page
Setup Page
Dis-
play
Parameter Name
Description
Range Default
Modbus Rela-
tive
Address
CIP
Class
Instance
Attribute
hex (dec)
Pro-
fibus
Index
Param-
eter ID
Data
Type
&
Read/
Write
[AC;LF]
[AC.LF]
Global
AC Line Frequency
Set the frequency to the
applied ac line power
source.
[``50] 50 Hz (3)
[``60] 60 Hz (4)
60 Hz Instance 1
Map 1 Map 2
886 1006
0x6A (106)
1
4
89 1034 uint
RWES
[R;typ]
[R.tyP]
Global
Ramping Type
[rate] Rate (81)
[``ti] Time (143)
Time Instance 1
Map 1 Map 2
- - - - 4414
0x7A (122)
1
26 (38)
- - - - 22038 uint
RWE
[P;typ]
[P.tyP]
Global
Profile Type
Set the profile startup to
be based on a set point or
a process value.
[StPt] Set Point (85)
[`Pro] Process (75)
Set Point Instance 1
Map 1 Map 2
2534 4354
0x7A (122)
1
8
- - - - 22008 uint
RWE
[`GSE]
[ gSE]
Global
Guaranteed Soak En-
able
Enables the guaranteed
soak deviation function
in profiles.
[`oFF] Off (62)
[``on] On (63)
Off Instance 1
Map 1 Map 2
2530 4350
0x7A (122)
1
6
- - - - 22006 uint
RWE
[GSd1]
[gSd1]
Global
Guaranteed Soak De-
viation 1
Set the value of the de-
viation band that will be
used in all profile step
types. The process value
must enter the deviation
band before the step can
proceed.
0.0 to 9,999.000°F or units
0.0 to 5,555.000°C
10.0°F or
units
6.0°C
Instance 1
Map 1 Map 2
2532 4352
0x7A (122)
1
7
- - - - 22007 float
RWE
[GSd2]
[gSd2]
Global
Guaranteed Soak De-
viation 2
Set the value of the de-
viation band that will be
used in all profile step
types. The process value
must enter the deviation
band before the step can
proceed.
0.0 to 9,999.000°F or units
0.0 to 5,555.000°C
10.0°F or
units
6.0°C
Instance 1
Map 1 Map 2
- - - - 4420
0x7A (122)
1
0x29 (41)
- - - - 22041 float
RWE
[`Si;a]
[ Si.a]
Global
Source Instance A
Set the digital source
for Wait for Event 1 in
profile.
5 to 12 5 Instance 1
Map 1 Map 2
- - - - 4390
0x7A (122)
1
0x1A (26)
- - - - 22060 uint
RWES
[`Si;B]
[ Si.b]
Global
Source Instance B
Set the digital source
for Wait for Event 2 in
profile.
5 to 12 5 Instance 1
Map 1 Map 2
- - - - 4392
7A (122)
1
0x1B (27)
- - - - 22061 uint
RWES
Note:
Some values will be rounded off to fit in the four-character display. Full values can be read
with other interfaces.
R: Read
W: Write
E: EEPROM
S: User
Set