Installation Guide

29
All fastener points are visibly covered with wedi joint sealant. All protrusions
(ie. plumbing xtures) are sealed into the wedi assembly with wedi gaskets
and sealant. All visible joints or seams in the installation are visibly covered
and reinforced with wedi Joint Sealant that is applied at over the seams.
Coverage of wedi Joint Sealant over all seams should be at least 1 in. on
either side of the seam. wedi Joint Sealant should be no less than 1/16 in.
thick to ensure strength. Do not add mesh tape into the wedi Joint Sealant;
this may put the waterproong performance at risk, and will not strengthen
the sealant or system resistance against movement-related stresses. It is re-
commended to add wedi mesh tape over seams featuring outside corners
(e.g. pony wall tops or curb deck transitions). The wedi mesh tape is applied
over nished and topically sealed seams once these are dry to the touch.
wedi joint sealant is then applied to cover the mesh. This method allows
you to apply more sealant consistently over a transition where it is difcult
to apply sufciently thick sealant. The mesh functions here as a thickness
gauge, but has no other function. Once wedi Joint Sealant has been applied
over all shower system seams, an optional water ood test may be perfor-
med in as little as 2 hours. Please ensure the sealant has cured sufciently
and has formed a skin no longer pliable or sticky leaving sealant residue upon
touch. The sealant is a moisture curing product that will react to cure very
slow when applied in a location with low relative humidity in the air, and it
will overreact and malfunction if exposed to too much water (e.g. ood test)
too early. The ood test should not exceed 24 hours, nor should the water
level exceed the height of the perimeter seams so that the fresh sealant may
continue to a full cure without too much weight added during that process.
wedi recommends testing the drain connection for a proper seal. While a full
surface ood test is not required for non-absorbing products like wedi, it may
be required by a building inspector. When tiling commences, no premixed
(“mastic”) tile adhesives may be used over wedi systems in any wet area in-
stallation. When tiling the wedi Shower Bases, incl. extensions or ramps, tile
thickness should generally be no less than 1/8 in. Choose setting materials
appropriate for the type of stone, ceramic, or glass tile as well as for a wet
area installation. When tiling with a square tile size of 2 in. × 2 in. or
more, install using a polymer modied cement based tile adhesive
and grout. When tiling with a square size of less than 2 in. × 2 in.,
install using a polymer modied cement based tile adhesive and use
a 100 % solids epoxy grout. When tiling with a square size of 1 in. × 1
in. or less, install using a 100 % solids epoxy tile adhesive and grout.
Only non-at bottom pebble stone installations, including small mosaics, may
be installed using polymer modied cement based tile adhesive and grout if
the mortar fully supports the tiles rounded undersides. All at bottom pebble
stone installation are subject to the general tile size based setting materials
recommendation outlined above. When installing non-square tile, the length
of the shortest tile edge(s) are considered as its square size for the purpose of
determining the choice of the setting materials as outlined above. Moisture
sensitive tile and stone, including marble, are best protected when installed
using solid epoxy tile adhesive and grout. It is recommended to verify with
manufacturers of mesh mounted tile that the adhesive and mesh used to
back the tile is appropriate for use in wet areas. It is important to achieve full
transfer of the thinset mortar through the mesh to the back of the tile. A best
practice we recommend is to remove the mesh when setting the tile.
All tile installations designed to receive heavier point loads (i.e. wheelchair
use) must be grouted using 100 % solids epoxy grout. Large format tile may
be installed over wedi Fundo shower bases. Cuts may have to be made in
consideration of the base’s slope lines and so that the tile can always be
fully supported by the tile adhesive setting bed, and the surface of the wedi
Base. Refer to TCNA guidelines for setting material coverage required by the
tile being installed in the wet room application here. Use only cleaners and
sealers free of acid or solvents on tile or grout installed over wedi product,
and apply only in amounts needed to treat the surface materials without
drenching the substrate. Follow setting materials manufacturer‘s recommen-
dations, and contact wedi with any questions, or regarding applications not
covered here.
Todos los puntos del sujetador están visiblemente cubiertos con el sellador de
juntas wedi. Todos los salientes (es decir, los accesorios de plomería) se sellan
en el montaje wedi con juntas wedi y sellador wedi. Todas las juntas o uni-
ones visibles de la instalación deben cubrirse y reforzarse de manera evidente
aplicando y allanando sellador de juntas wedi sobre las uniones. El sellador
de juntas wedi debe cubrir todas las uniones al menos 1 in. (25 mm) en cada
lado de la unión. Para garantizar su resistencia, se debe usar un espesor de
sellador de juntas wedi no inferior a 1/16 in. (1.6 mm). No agregue cinta de
malla al sellador de juntas wedi; esto podría comprometer el efecto imper-
meabilizante y no reforzará la resistencia del sellador o del sistema frente a
los esfuerzos relacionados con el movimiento. Se recomienda agregar la cinta
de malla wedi a las uniones que tienen esquinas exteriores (por ejemplo,
supercies superiores de paredes cortas o transiciones de plataformas de
bordillos). La cinta de malla wedi se aplica en las uniones acabadas y selladas
localmente una vez que dichas uniones estén secas al tacto. A continuación,
se aplica el sellador de juntas wedi para cubrir la malla. Este método le per-
mite aplicar más sellador de forma consistente sobre una transición en la
que es difícil aplicar un sellador lo sucientemente grueso. La malla funciona
aquí como medidor de espesor, pero no tiene ninguna otra función. Una
vez que se haya aplicado el sellador de juntas wedi en todas las uniones del
sistema de ducha, se puede realizar una prueba de inundación opcional una
vez transcurridas 2 horas. Asegúrese de que el sellador se haya curado lo su-
ciente y que haya formado una película que no sea exible ni esté pegajosa
dejando residuos de sellador al tocarla. El sellador es un producto de curado
de humedad que reaccionará al curado muy lentamente cuando se lo aplique
en una ubicación con una humedad relativa baja en el aire, y reaccionará
excesivamente y presentará defectos si se lo expone a demasiada agua muy
pronto (por ejemplo, con una prueba de inundación). La prueba no debe so-
brepasar las 24 horas ni el nivel de agua debe superar la altura de las uniones
perimetrales, de modo que el sellador fresco pueda endurecerse por com-
pleto sin que se le añada demasiado peso en el proceso. wedi recomienda
comprobar que la conexión de drenaje haya quedado correctamente sellada.
Si bien no se requiere una prueba de inundación de toda la supercie para
los productos no absorbentes como wedi, es posible que sí lo requiera una
inspección de construcción. Cuando se empiece a enlosar, no deben aplicarse
adhesivos de losetas (“masilla”) premezclados sobre sistemas wedi instalados
en espacios húmedos. Cuando se enlosen las bases de ducha wedi, incluidas
extensiones y rampas, el espesor de la loseta no debe ser, en general, menor
de 1/8 in. (3.2 mm). Elija materiales ligantes que se adecúen al tipo de piedra,
cerámica o vidrio de la loseta, así como a instalaciones en espacios húmedos.
Cuando se enloce con un tamaño cuadrado de 2 pulg. × 2 pulg. o
más, realice la instalación con una lechada y un adhesivo a base de
cemento modicado con polímeros. Cuando se enloce con un tamaño
cuadrado inferior a 2 pulg. × 2 pulg., realice la instalación con un
adhesivo a base de cemento modicado con polímeros y utilice una
lechada epóxica de 100 % sólidos. Cuando se enloce con un tamaño
cuadrado de 1 pulg. × 1 pulg. o menos, realice la instalación con una
lechada y un adhesivo epóxico de 100 % sólidos para losetas. Solo
instalaciones de cantos rodados de fondo no plano, incluidos parcialmente
los mosaicos pequeños, pueden instalarse usando una lechada y un adhesivo
a base de cemento modicado con polímeros si el mortero admite un soporte
total de la parte inferior redondeada de las losetas.
EN
ES
wedi Fundo
®
Primo Instructions d’installation du wedi Fundo
®
Primo sur planchers en bois ou en béton