Make sure the C Brackets are
mounted in a level position
(assuming a level base plate)
and use flathead Phillips self-
drilling screws with wings pro-
vided by wedi. Fasten through
the base plate and into the
two (2) metal claws resting
between base plate and wood
floor top.
Install one (1) C bracket against
the wall and centered between
each pair of floor joists (if joist
spacing 16“ [406.4 mm] o.c.).
If the Joist spacing is greater
than 16“ (406.4 mm) o.c. please
install two (2) C brackets cen-
tered between each pair of floor
joists.
10
Dry fit C brackets to the edge of the wood floor to ensure C Brackets can
be installed for full support along the edge of the floor plate. Use a wood
block or hard rubber mallet to push the brackets in position.
Use flat head Phillips self-drilling screws with wings provided by wedi
to fasten C brackets to the edge of the wood floor plate at the open
side of the future shower area. Fit brackets between flanges of joist/wall
brackets. Use two (screws) to fasten this bracket through the wood floor
and into the lower claws. When working with floor joists with a spacing
greater than 16“ (406.4 mm), use 1 full C bracket and another one cut
to length for full support along the edge of the floor.
12
04
13
05 07
Measure and mark to cut wood
strips tightly fitting into the re-
cess bracket support system be-
tween joists, wall framing and
regular subfloor. Leave a 1/8“
(3.2 mm) gap between wood
strips and brackets so the wood
may move without creating too
much tension.
Fasten the next bracket on the
other side of the floor joist.
Stagger the tabs, so you may
need to cut the brackets.
Cut the wood floor strips incl.
the strip for the drain area fea-
turing a 6 1/2“ (165.1 mm) di-
ameter hole to be seated over
the center of the floor waste
pipe.
Repeat process shown under
step 4 and install joist brackets
to all exposed joists.
06
Place C brackets at the wall
sides. The C brackets are ins-
talled at both ends of the recess
area rst and then along the
wall / side every 12“ (304.8 mm)
(center of C bracket to center of
C bracket).
The C brackets are inserted
with their claws between floor
surface and underside of the
base plate. Use a wood block
or a hard rubber mallet to push
C brackets into position.