Install Instructions

Boiler
Model
Number
!
Water Steam
PIDN PIDN
EG-30
PEG-30
84.3
83.0
EG-35
PEG-35
83.6
82.9
EG-40
PEG-40
84.0 82.9
EG-45
PEG-45
83.5 82.9
EG-50
PEG-50
83.8 82.8
EG-55
PEG-55
83.8 82.8
EG-65
PEG-65
84.0 83.0
EG-75
82.7 82.4
Part Number 550-142-782/1112
39
EG
&
PEG SERIES 5
s
EGH SERIES 5 GAS-FIRED BOILERSBOILER MANUAL
Notes (Table 16)
*
Add prefix “P” for package boiler completely assembled and
wired with jacket and controls (PEG-30-S through PEG-65-S
only).
1.
%'THRU: Add suffix “PID” or “PI” for electronic ignition
(30-65 — damper required in U.S.; optional in Canada); add
“N” for natural; add “L for propane; add “W” for water; add “S”
for steam; add T” for tankless heater; add “P” for provisional
tankless heater.
%'(  : Add suffix “PI” for electronic ignition
(damper available on PI only); add “N” for natural; add “L
for propane; add “S” for steam; add “T for tankless heater
(tankless available on EGH-85 thru 125 PI Steam; EGH-85
and 95 SP Steam only); add “P” for provisional tankless heater.
%'( THRU : Add suffix “PI” for electronic ignition
(damper available on PI only); add “T for tankless heater.
2. Based on standard test procedures prescribed by the United
States Department of Energy.
%'(THRU%'( Gross output.
3. EGH-105 thru 125 may be installed at altitudes of 2,000-4,500
feet subject to acceptance by Provincial Inspections Authority
based on field tests of individual installations.
4. Net AHRI ratings are based on net installed radiation of
sufficient quantity for the requirements of the building and
nothing need be added for normal piping and pick-up. Water
ratings are based on a piping and pick-up allowance of 1.15;
steam ratings on an allowance of 1.333. An additional allow-
ance should be made for unusual piping and pick-up loads.
Consult local Weil-McLain representative.
4ABLE DOE seasonal efficiencies
Ratings
Boiler
Model
Number
0–2,000
feet altitude
2,000–4,500
feet altitude
(Canada)
Net AHRI Ratings
Chimney
Size
Boiler Water
Content
(Gallons)
Input

DOE Heating
Capacity
Gross Output
Input

(Output)

Sq. Ft.
Steam
Steam
Btuh
Water
Btuh
Water Steam

   
*EG-30-
    196    12.3 8.4
*EG-35-
    258    12.3 8.4
*EG-40-
    325    14.8 9.8
*EG-45-
    392    14.8 9.8
*EG-50-
    454    17.3 11.2
*EG-55-
    521    17.3 11.2
*EG-65-
    654    19.8 12.6
EG-75-     770    22.3 14.0
EGH-85-S     760   15.4
EGH-95-S     868   16.8
EGH-105-S     977   18.2
EGH-115-S        19.6
EGH-125-S        21.0
4ABLE Ratings
DOE