Brochure
WM2011_BRO_019_SGO
7"diam. 7"diam.
20¼
35⅝
1⅛
3¾
26⅞
water line
15
clearance
for
tankless
heater
7¾
A2
A1
Packaged* Front
Intermediate
Semi-Packaged* Front Side Back
20¼
3¾
7⁄ 4⁄
10¼
15
clearance
for
tankless
heater
for 7
vent pipe
7¾
A2
E2
S2
U2
U3
A3
A
B
U1
B2
R1
H
L
A2
A3
26⅞
water line
4⅜
diam.
burner
opening
heater location
1⅛
30⁄
9½
15½
2⁄
2⁄
A1
B1
S1
E1
L
P
6¼
3¾
3⁄
14⅛
7⁄
14
approx.
7 diam.
29⁄
In the interest of continual improvement in product and
performance, Weil-McLain reserves the right to change
specifications without notice.
Model* SGO-3 SGO-4 SGO-5 SGO-6 SGO-7 SGO-8 SGO-9
AHRI Burner Capacity (GPH)
1
0.95 1.20 1.45 1.75 2.00 2.30 2.55
Input Rating (MBH)
3
133 168 203 245 280 322 357
DOE Heating Capacity (MBH)
1, 2
114 144 174 210 240 266 295
AFUE 85.0% 85.0% 85.0% 85.0% 85.0% —
4
—
4
Net AHRI Steam Ratings (MBH)
3
86 108 131 158 182 200 221
Steam (Sq. Ft.)
5
358 450 546 658 758 833 921
Tankless Heater Intermittent Draw Rating (GPM)
6
3.25 3.50 3.75 4.00 4.00 4.00 4.00
Draft Loss Through Boiler (in. w/c)
7
.020 .010 .015 .015 .015 .025 .030
Chimney
Size
Rectangular (in.) 8 x 8 8 x 8 8 x 8 8 x 8 8 x 8 8 x 12 8 x 12
Round (in.) 6 6 7 7 8 8 8
Height (Ft.) 15 15 15 15 15 20 20
Approx. Shipping Weight (Lbs.) 600 705 820 920 990 1090 1195
* Boiler order options include
Packaged boiler: Assembled block with jacket, collector hood and controls installed (order burner separately); sizes 3–6.
Semi-packaged boiler: Assembled block with jacket and collector hood installed (order burner and trim separately); sizes 3–6.
Knocked-down boiler: Assembled block, all other components are cartoned and shipped separately; all sizes.
DIMENSIONS
RATINGS
SGO-3 1-2½ 2 – 13½ 16⅞ ¾ ¾
SGO-4 1-2½ 2 – 16⅝ 20 ¾ ¾
SGO-5 1-2½ 2 – 19⅞ 22⅛ ¾ ¾
SGO-6 2-2½ 2 19 23 26¼ ¾ ¾
SGO-7 2-2½ 2 22⅛ 26⅛ 29⅜ ¾ ¾
SGO-8 2-2½ 2 25¼ 29¼ 32½ ¾ ¾
SGO-9 2-2½ 2 28⅜ 32⅜ 35⅝ ¾ ¾
Model
Supply
(in.)
Return
(in.)
Dimension (in.)
Tankless Heater
#35-S-29
Steam Steam A B L
Inlet & Outlet
(NPT) (in.)
Temp Control
(NPT) (in.)
Tapping
Location
Size
(in.) Steam
A 1½ Skim tapping
A 2½ Supply
A 2½ Supply (SGO-6 through 9)
B 1½ Plugged
B 2 Return
E ½
Pressure gauge & limit control
(when probe LWCO is used)
E & E ½ Low water cuto (float-type)
H ¾ Drain valve
L ¾
Pressure gauge & limit control
(when probe LWCO is used)
P ¾ Low water cuto (probe-type)
R ¾ Relief valve
S & S ½ Gauge glass
U 1
Take-o for indirect-fired water
heater or separate zone
U ¾
Tankless heater operating
control (SGO-6 through 9)
U* ¾
Tankless heater operating
control (SGO-3 through 5)
STANDARD EQUIPMENT:
BOILER
■
Factory tested and assembled
cast iron section assembly
(jacket and collector hood are not
assembled on 7, 8 and 9 section blocks)
■
Insulated steel jacket
■
Aluminized steel flue collector hood
with flue cap on top outlet (convertible
to rear outlet)
■
Swing-away burner mounting door
■
Refractory blanket and target wall in
combustion area
■
Tankless heater opening cover plate
■
Electrical junction box with
wiring harnesses
■
Junction box cover plate with service
switch
■
Two vent pipe brackets
■
Drain valve
■
Barometric damper
■
Oil vent damper
■
High limit pressure control
■
Low water cuto; Packaged units only
(float or probe type)
■
15 PSI ASME relief valve
■
Steam pressure gauge
■
Siphon
■
Gauge glass, cocks and guard
OPTIONAL EQUIPMENT:
■
High-eciency flame-retention Oil
Burner (Beckett AFG, Carlin EZ or Riello).
Specify 2-stage fuel unit (optional,
Beckett)
if required.
■
Tankless heaters and controls
■
Low water cutos
(float or probe type)
■
Weil-McLain five- and ten-year
homeowner protection plan
■
Weil-McLain indirect-fired
water heaters
LIMITED TRANSFERABLE
WARRANTY:
■
Residential: 10 Years Heat Exchanger;
2 Years Parts
■
Commercial: 10 Years Heat Exchanger;
1 Year Parts
1
No. 2 fuel oil-Commercial Standard Specification
CS75-56. Heating value of oil-140,000 BTU / Gal.
2
Based on standard test procedures prescribed by
the United States Department of Energy—see ratings
chart in boiler manual for further detail.
3
MBH refers to thousands of BTU per hour.
4
Rating under “DOE Heating Capacity” for SGO-8 and
-9 is AHRI gross output. DOE ratings do not apply to
boilers above 300 MBH.
5
Net AHRI ratings are based on net installed radiation
of sucient quantity for the requirements of the
building and nothing need be added for normal piping
and pickup. Steam ratings are based on a piping and
pickup allowance of 1.333. An additional allowance
should be made for unusual piping and pickup loads.
6
All boiler sizes use number 35-S-29 tankless heater.
Tankless heater rating is in gallons of water per
minute, heated from 40°F to 140°F with 200°F boiler
water temperature-tested in accordance with I-W-H
Testing and Rating Standard for Indirect Tankless
Water Heaters Test with Boilers.
7
Listed draft losses are for standard burner settings.