Aqua Pro Submittal

Specications
AHRI Certified Data
180° F boiler water entering | 58° F to 135° F domestic water
Potable
Water
Volume
Heat
Source
Water
Volume
First Draw
Rating
Standby
Heat Loss
Continuous
Draw Rating
First Hour
Rating
Minimum
Heat
Output
Rate
Minimum
Heat
Source
Flow Rate
Heat
Source
Friction
Loss
(Gal) (Gal) (Gal/hr)
Degrees F
per hour
(Gal/hr) (Gal/hr) (MBH) GPM Feet w.c.
30
30.0 .3 22 .8 177 199 115 8.0 18.7
55
55.0 .3 40 .6 177 217 115 8.0 18.7
80
80.0 .6 66 .4 315 381 199 14.0 16.0
119
119.0 .8 96 .4 381 477 244 14.0 20.0
These ratings were obtained with a heat source output rate of 234,000 Btu/h at a heat source flow rate of 14 gpm.
Other results shall be obtained under dierent conditions.
Dimensions
Shipping
weight
(approx.)
A
Overall
Diameter
B
Inner Tank
Diameter
C
Height to
Fitting
D
Height of
Jacket
Connections
E
DHW
In/Out
F
Boiler
water
In/Out
Inches Inches Inches Inches
Inches
MNPT
Inches
MNPT
Pounds
30
22-3/4 18 40-1/2 37-3/4 3/4 3/4 70
55
28 24 41 38-1/8 3/4 3/4 95
80
28 24 53-1/2 50-3/4 1-1/2 1 125
119
28 24 74 71-1/4 1-1/2 1 155
1. Boiler water inlet
2. Boiler water outlet
3. Cold domestic water inlet
4. Hot domestic water outlet
5. Electronic digital controller with
adjustment knob
6. Drain (3/4")
In the interest of continual improvements in product and performance, Weil-McLain reserves the right to change specication without
notice. For reference use only-see product manual for detailed information.