Item Brochure

Welch Allyn Blood Pressure Products
featuring DuraShock
Technology
Patents: 5,966,829; 6,036,718; 6,082,170; 6,120,458; 6,168,566; 6,234,972. Additional patents pending.
© 2006 Welch Allyn, Inc. All rights reserved. Welch Allyn
®
and DuraShock
are trademarks of Welch Allyn.
SM2401 Rev D Printed in USA
4341 State Street Road, PO Box 220, Skaneateles Falls, NY 13153-0220 USA
(p) 800.535.6663 (f) 315.685.2174
www.welchallyn.com
Welch Allyn Tycos DS58 Classic
Hand gauge, thumbscrew release valve
DS58 Aneroid only
DS58-11 Aneroid with adult durable one-piece cuff and zipper case
DS58-11CB Aneroid with adult durable two-piece cuff and bladder and zipper case
DS58-MC Aneroid with large adult, adult, small adult, and child print durable one-piece cuff and zipper case
DS58-MCCB Aneroid with large adult, adult, and child print durable two-piece cuff and bladder and zipper case
DS58-PD Aneroid with child print, small child, infant, and newborn durable one-piece cuff and zipper case
DS58-PDCB Aneroid with child print, small child, and infant durable two-piece cuff and bladder and zipper case
5085-10 Small zipper case
5085-11 Large zipper case
Welch Allyn Tycos DS48 Classic
Integrated gauge (cuff mounted)
DS48 Aneroid only
DS48-11 Aneroid with adult durable one-piece cuff and zipper case
5085-10 Small zipper case
Welch Allyn Tycos DS48A Classic
Pocket gauge (clips on two-piece cuff and bladder)
DS48A Aneroid only
DS48-11CB Aneroid with adult durable two-piece cuff and bladder and zipper case
5085-10 Small zipper case
Welch Allyn DS66 Trigger
Hand gauge, trigger valve
5098-31 Aneroid only
5098-27 Aneroid with adult durable one-piece cuff and zipper case
5098-27CB Aneroid with adult durable two-piece cuff and bladder and zipper case
5098-30 Aneroid with large adult, adult, small adult, and child print durable one-piece cuff and zipper case
5098-30CB Aneroid with large adult, adult, and child print durable two-piece cuff and bladder and zipper case
5085-07 Single zipper case
5085-08 Double zipper case
Welch Allyn DS45 Integrated
Integrated gauge (cuff mounted)
DS45 Aneroid only
DS45-11 Aneroid with adult durable one-piece cuff
DS45-11C Aneroid with adult durable one-piece cuff and zipper case
DS45-11CB Aneroid with integrated gauge adapter and adult durable two-piece cuff and bladder
5085-07 Single zipper case
W
elch Allyn DS44 Integrated
Integrated gauge (cuff mounted)
DS44 Aneroid only
DS44-11 Aneroid with adult durable one-piece cuff
DS44-11V Aneroid with adult durable one-piece cuff and color bumper variety pack
DS44-11C Aneroid with adult durable one-piece cuff and zipper case
DS44-11CB
Aneroid with integrated gauge adapter and adult durable two-piece cuff and bladder
5085-09 Single zipper case
Welch Allyn Platinum Series
A premium professional line of quality
sphygmomanometers
Welch Allyn Gold Series
A professional line of quality
sphygmomanometers
Welch Allyn Silver Series
An entry-level line of quality
sphygmomanometers
Welch Allyn Bronze Series
An economy line of quality
sphygmomanometers
Welch Allyn Part Numbers
In traditional aneroid sphygmomanometer design, several
delicate gears and springs convert and amplify vertical
movement of the pinion to rotational movement to turn
the pointer. The DuraShock gear-free design, however,
uses a superior single helix spring to directly convert the
vertical movement of the pinion to rotation of the pointer
without the use of a multi-step gear arrangement.
By creating a gear-free design, Welch Allyn products with
DuraShock technology have fewer moving parts, providing a
gauge that is shock resistant and lighter than traditional
gauges. Until now, a dropped sphygmomanometer required
recalibration or replacement. The DuraShock gauges in the
Bronze, Silver, and Gold lines can fall 30 inches onto a hard
surface and still remain accurate. The DuraShock gauges in
the Platinum line can fall 60 inches onto a hard surface and
still remain accurate.
How DuraShock Technology Works
Specifications
The W
elch Allyn DuraShock aneroid sphygmomanometer is accurate to
+
3 mmHg or 2%
of the reading above 200 mmHg. This product will maintain the safety and performance
characteristics specified at temperatures ranging from 10º C to 40º C at a relative humidity
level not to exceed 90%.
Standards
American National Standard ANSI/AAMI, SP10: 2002, Manual, electronic,
or automated sphygmomanometers.
American National Standard ANSI/AAMI, SP9: 1994, Non-automated
sphygmomanometers (model DS44 and DS45 only)

Summary of content (2 pages)