UMH 160 Quick Installation Guide V1.1-W UMH160 Integrated Digital Receiver Quick Installation Guide Wellav Technologies Ltd.
UMH 160 Quick Installation Guide V1.1-W Preface About This Document This document provides introductions and guidelines to users about how to install and operate this equipment quickly. Disclaimer Wellav Technologies Ltd. assumes no responsibility for errors or omissions that may appear in this publication. It reserves the right to change this publication at any time without notice.
UMH 160 Quick Installation Guide V1.1-W There are potential risks. If ignore these texts, it may cause damage to the device, data loss, equipment performance reduce or unpredictable results. Tips that help you to solve problems or save your time. Remarks. Additional information to the text, in order to emphasize something. Revision History The revision history lists the modification history. The newest one contains all the modifications of the past revision. V1.00: First revision.
UMH 160 Quick Installation Guide V1.1-W Content 1. Safety ............................................................................................................................ 5 2. Check Package and Accessories .................................................................................. 6 3. Physical specifications ................................................................................................... 7 4. 5. 6. 3.1 Physical Specifications ...............................
UMH 160 Quick Installation Guide V1.1-W 1. Safety z To avoid electric shock hazards, do not open the receiver; refer service to qualified personnel only. z Do not expose the device in the sunlight, and keep it away from the heat source. z Do not block ventilation holes of the device so that air can circulate freely. z Switch the device off whenever it remains out of service for an extended period.
UMH 160 Quick Installation Guide V1.1-W 2. Check Package and Accessories The Receiver package includes the following accessories: z UMH160 Base Unit x1 z Power cord x1 z Earth cord x1 z BNC cord x1 z BNC-RCA cord x2 z User manual Disc x1 Please contact the supplier if it is inconsistent with the actual package. Wellav Technologies Ltd.
UMH 160 Quick Installation Guide V1.1-W 3. Physical specifications 3.1 Physical Specifications Items Index Power AC 90V-260VAC, 50/60Hz Power Consumption Approx 125W Size 1RU Dimension 482mm(L) x44mm(W) x 393mm(H) Net Weight Approx 3.8Kg Gross Weight Approx 5Kg 3.
UMH 160 Quick Installation Guide ● V1.
UMH 160 Quick Installation Guide V1.1-W 4. Front Panel and Rear Panel 4.1 Front Panel 1 2 3 4 5 6 7 8 PIC-4.1-1 Item No. Functionality 1 Power status indicator 2 (Signal) Lock status indicator 3 Alarm status indicator 4 LED displaying screen 5 CI SLOTS 6 KEY PADS, including Up/Down/Left/Right arrow keys 7 Menu. To enter the menu and the quit function of the sub menus. 8 ESC. The quit function of the menu. 4.2 Rear Panel Wellav Technologies Ltd.
UMH 160 Quick Installation Guide 5 1 2 3 4 6 8 V1.1-W 9 7 8 9 PIC-4.2-1 10 11 12 13 Item No. Functionality 1 TS/IP: TS stream input and output as IP format 2 AES/EBU: Professional digital Audio output with XLR connector. 3 HDMI: Output high quality picture and sound with one cable. 4 Cr/Cb/Y: Component output. 5 VIDEO /AUDIO: Video signal output jack and Left/right audio output jack. 6 ASI IN: BNC connector for TS input. 7 CVBS OUT: Output video with BNC interface.
UMH 160 Quick Installation Guide z V1.1-W Protective Ground - The protective ground lead of the building's electrical installation should comply with national and local requirements. z Environmental Condition - The installation site should be dry, clean, and ventilated. Do not use this equipment where it could be at risk of contact with water. To avoid electric shock, make sure the rack has been correctly grounded before switching device on the. PIC-5.
UMH 160 Quick Installation Guide V1.1-W PIC-5.1-2 5.2 Wiring Connection Before setting up the connection, please turn off the equipment and all other connected external devices. The equipment and all connected external devices are required grounded. Turn on the devices only after the wiring connection is completed. Otherwise, the device may be damaged. Follow the below connection diagram to set up cable connection: 1 3 4 2 5 PIC-5.
UMH 160 Quick Installation Guide V1.1-W the equipment, please separate the connection of management port and TS/IP output port to different switch. The switch with management port connected should be without large data processing. The TS/IP port can work for input and output simultaneously. User only needs to connect one RJ45 cable to the TS/IP port of the device. 5.
UMH 160 Quick Installation Guide V1.1-W 6. Operation Instructions 6.1 Powering Up & Initializations Before powering-up the device, make sure that all cabling is correctly connected (refer to chapter PIC-5-2-1). The device is correctly connected to the power inlet and grounded. Switch on the equipment through the back power switch, the unit is powered up and start the initialization. The LCD screen is lighted up, and display information as following: UMH160 Setting System PIC-6.
UMH 160 Quick Installation Guide V1.1-W enter the configuration menu. z Enter “Menu”: z Press “MENU” button to enter main menu. Exit Menu/Back to parent Menu Upon completion of configuration settings, press “MENU” button until you go back to the Parent Menu. z z You can also go back to Parent Menu directly by pressing “ESC” button once. Enter Sub-Menu Press MENU button to enter main menu. Select a sub-menu by pressing UP and DOWN button. Press OK button on the selected sub-menu.
UMH 160 Quick Installation Guide V1.1-W 6.2.3 Configuration through WEB Management Accessing the equipment through web can be very convenient for remote configuration of the equipment. Relative to the front panel settings, web operation can provide a more user-friendly man-machine interface, and less limits in space. For quick installation, web operation is highly recommended. In this installation guide, operation instruction is based on web style.
UMH 160 Quick Installation Guide V1.1-W User can change the password after log on the device. Please refer to chapter XXXX of this document for the details. (Referring chapter 6.3.4) Possible reasons for unsuccessful log on: z z IP address/ network mask/gateway don’t match with the management PC’s z User name/password is wrong. z The device is connected to the wrong interface.
UMH 160 Quick Installation Guide 6.3 V1.1-W Quick Configuration on Key Parameters 6.3.1 Check “Status” tab Click the “status” tab on the left area and then the status information will show on the right interface as following, where you can check the main information of the device. PIC-6-3-1 6.3.2 Configure parameters of signal input modules Firstly, click the receiver menu to obtain the receiver interface, where you can configure the detailed parameter as follows: Wellav Technologies Ltd.
UMH 160 Quick Installation Guide V1.1-W Step one Step three Step four Step two PIC-6-3-2 z Tuner IN If you need to receive the signal from satellite via the device, just connect the satellite siganl to the tuner port and operate as follows: -Step one: PIC-6-3-3 Choose the signal as input ,there are three options:ASI, Tuner and IP, here we choose tunel as siganl source. After confirm the signal source, it is able to go for further configuration.
UMH 160 Quick Installation Guide V1.1-W PIC-6-3-4 z SATELLITE FREQUENCY (MHz): this is the satellite down conversion frequency, every transponder has one frequency, and this parameter can be obtain from the satellite program provider or at www.lyngsat.com z SYMBOL RATE (KBaud): every transponder has one symbol rate; this parameter can be obtain from the satellite program provider or at www.lyngsat.com z LNB LO.
UMH 160 Quick Installation Guide V1.1-W -Step four After that press the “Submit” button to save your settings, and click “Refresh” button to refresh the screen to check if the signal is locked. Step two z ASI IN Step One Step three PIC-6-3-5 -Step one When choosing the ASI signal as input, check the ASI siganl first to ensure a high-quality source, then connect the ASI signal to the ASI interface on rear panel.
UMH 160 Quick Installation Guide V1.1-W z IP IN -Step one When need to choose IP stream as input source, click the sub-menu “IP Input” sub-menu in “IP” menu. Then it can turn to the IP parameter interface. Step one PIC-6-3-6 -Step two Before the receiving of IP signal, make sure the IP address of the IP board is correctly set. It should be set to be compliant with the signal source. Wellav Technologies Ltd.
UMH 160 Quick Installation Guide V1.1-W Step Three Step two PIC-6-3-7 -Step Three Then, set the “Enable” item to be “ON” to access the IP channel and set the source IP address, Source Port and Protocol. The Source IP address shall be in the same section with that of signal source, and the Source Port and protocol shall stay same with that of signal source. -Step Four Press “Submit” button to confirm the parameter.
UMH 160 Quick Installation Guide V1.1-W Step one Step two PIC-6-3-8 -Step One: choosing programs z Playing Program: This interface, all the programs received will be listed in “Source Select” region. By changing the program’s operation, you can determine which program to transmit. PIC-6-3-9 If the input signal is not locked or searched, the “program” section shows empty. User cannot do any setup for the moment.
UMH 160 Quick Installation Guide V1.1-W PIC-6-3-10 The device decoding output is via its CVBS or HDMI output ports. For each time only one program can be set to decoding output. z Audio: In addition, you can configure the information of Audio such as volume, and audio language, as following: PIC-6-3-11 o AUDIO Volume: Set the output audio level from 0 to max. 49. o AUDIO LANGUAGE: Select different audio language if there are multiple audio PIDs contained in the signal.
UMH 160 Quick Installation Guide V1.1-W successful transmission, you should make sure the signal has already been locked. . z IP Out: When need to choose IP stream as input source, click the sub-menu “IP Input” in “IP” menu. Then it can turn to the IP parameter interface. Step one PIC-6-3-13 -Step two Before the setting of IP output channels, you should choose the IP channel that you want to use.
UMH 160 Quick Installation Guide V1.1-W IPSourcePort and UDPDestProtocol. The IPDestAddress is the address which you want to send the streams to. (Refer to chapter 6.3.3.3) Enable the FEC function and set the parameters, if you want this Function. ColFEConly: No means both Col and Row FEC; Yes means Col FEC only. -Step Four Here it it able to check the programs that converted in the IP channel. 6.3.3.
UMH 160 Quick Installation Guide V1.1-W 1) The IRD supports IGMP v3, please note the IGMP version that your router supports. 2) The ‘Speed Mode’ in front panel should be set the same to your switch/router. 3) The quantity of programs transmitted via IP channel depends on the speed mode (10M/100M/1000M) of the switch or router, which connects to the IRD.
UMH 160 Quick Installation Guide V1.1-W PIC-6-3-17 6.3.5 Check “Status” again Turn to status page to check if the configuration has come into effect. PIC-6-3-18 This is the brief introduce of quick installation, if need more detail or complete information for the device please refer to the user manual. Wellav Technologies Ltd.