Product Manual

STARTING THE GENERATOR
To start the generator, perform the following steps:
1. Place the generator outside on a dry, level surface.
2. Check there is sufficient level of oil in the crankcase. Add oil if nec-
essary (refer to “Add/Check Oil” an page 8).
3. Check there is sufficient level of gasoline in the fuel tank. Add fuel
is necessary (refer to “Add/Check Gasoline” on page 9).
4. To maximize safety, make sure the generator is properly grounded
(Refer to “Ground the Generator” on page 9).
Before starting the generator, make sure you have read and performed the steps in the “Generator Preparation”
section of this manual. If you are unsure about how to perform any of the steps in this manual please call (800) 232-
1195 M-F 8-5 CST for customer service.
STARTING THE GENERATOR
5. Make sure all electrical devices are unplugged from the generator
during ignition. Otherwise it will be difficult for the engine to start.
6. Turn the fuel valve to the ON position (Fig. 7).
7. Move the choke lever to the CLOSE position (Fig. 7).
8. Set the engine switch on the control panel to the ON position.
9. Pull on the recoil starter handle (Fig. 10) slowly until a slight resis-
tance is felt, then pull quickly to start the engine. Return cord gently
into the recoil starter. Never allow the cord to snap back.
10. If engine fails to start, repeat step 9.
NOTE: After repeated failed attempts to start the engine, please con-
sult the troubleshooting guide before attempting again. If problems
persist please call (800) 232-1195 M-F 8-5 CST.
11. Once the engine has started, slowly return the choke lever all the
way to the OPEN position.
12. Allow the engine to run for several minutes before attempting to
connect any electrical devices. This allows the generator to stabilize its
speed and temperature.
Fig. 10
ON
OFF
FUEL VALVE
CHOKE LEVER
Fig. 7
Fig. 8
Fig. 9
ON
OFF
OIL LEVEL SHUTDOWN
The generator is equipped with a low oil pressure shutoff that shuts down the engine when the oil level is too low
to protect the unit from damage. The oil level of the engine should be checked before each start to ensure that the
engine crankcase contains sufficient lubricant.
11