Installation Guide

General Information
This control system provides safe and con-
venient remote on/off switching of one 120V
load. The system consists of the following:
Controller ASB-BOX-1
Air Button ASB-CHB
Air Hose ASB-hose
Operation
The system works by displacing sealed air.
Pressing the Air Button displaces sealed air
through the connecting Air Hose which acti-
vates the pressure sensitive electrical switch
in the controller. This completes the electrical
circuit, turning on the disposal. The circuit
remains on until the button is pressed and
released again.
Caution
To avoid damage to the appliance and con-
troller, do not cycle rapidly. Do not connect
other equipment to the outlet with disposer.
Electrical Rating
15 Amps (non-inductive) @ 120 VAC
1. The Air Button must be mounted within 6
feet of the Controller. Select a location, con-
venient for the user. See suggested Locations
below.
2. Drill a 1-3/8” diameter hole at the desired
location. The Air Button can be mounted
through surfaces from 1/16” to 2” thick.
3. Remove the nut and washers from the
Air Button body. Apply a very thin bead of
silicone caulking under the button flange to
provide a tight seal. Insert the body through
the hole, slide on the washers and secure the
nut. Do not over tighten.
4. Connect one end of the Air Hose to the
air button, routing the hose to the Controller
location. Use care to ensure the hose will not
be kinked or damaged.
5. Attach the other end of the hose to the
Controller and plug the controller in to a 120 V,
continuously charged outlet.
6. Make sure nothing is fouling the disposal.
Plug in the disposal to the Controller outlet.
Caution
The disposal may begin to operate. If it does,
press the Air Button to turn it off.
7. Check the system for proper operation.
Press the Air Button to turn on the disposal.
Press again to turn off the disposal.
Installation Instructions
ASB-1
Disposer Air Operated Switch
Mount Air Button on wall,
counter top, sink or cabinet
within six feet of the controller.
Controller
Air Hose
Disposal
Cord
120V - 15 amp
Dedicated Outlet
1. El Botón Aéreo debe montado dentro de 6
pies del controlador. Seleccione una ubi-
cación, conveniente para el usuario. Vea la
Ubicación sugerida abajo.
2. Taladre un 1-3/8” hoyo de diámetro en la
ubicación desada. El Botón Aéreo puede ser
montado por supercies de 1/16” a 2” grueso.
3. Quite la tuerca y las arandelas del cuerpo
Aéreo de Botón. Aplique una cuenta muy del-
gada de para proporcionar un sello apretado.
Inserte el cuerpo por el hoyo, el resbaladero
en las arandelas y asegure la tuerca. Haga no
sobre aprieta.
4. Conecte un n de la manga al controlador
y conecte el controlador a un 120V continu-
amente salida de carga.
5. Conecte el otro n de la manga al controla-
dor y conecte el controlador a un 120V salida
cargada continua.
6. Aségurese nada contamina la disposición.
Conecte la disposición a la salida del contro-
lador.
Cuidado
El depositor puede empesar a operar. Sí
esto sucede preción el Aéreo de Botón para
apagar.
7. Revisar el sistema para funciona correcta-
mente. Presionar el Aéreo de Botón para
iniciar la recogida de basuras. Pulse otra vez
para apagarlo.
Included in Package
3”
2-1/8”
Front
Back
ASB-CHB
ASB-BOX-1
ASB-HOSE
Instrucciones de Instalación
Westbrass
2429 E. Olympic Blvd., Los Angeles, CA 90021
(800) 39-BRASS (213) 627-8441
www.westbrass.com info@westbrass.com