KWchenAid” HOME APPLIANCES 30” (76.2 cm) and 36” (91.4 cm) Gas Cooktops IMPORTANT: Read and save these instructions. IMPORTANT: Installer: Leave Installation Instructions with the homeowner. Homeowner: Keep Installation Instructions for future reference, Save Installation Instructions for local electrical inspector’s use. Part No. 3189086 Rev.
Before you start... Proper installation is your responsibility. Make sure you have everything necessary for correct installation. It is the responsibility of the installer to comply with the installation clearances specified on the model/serial rating plate. The model/serial rating plate can be found on the bottom of the cooktop. Check location where cooktop will be installed. The location should be away from strong draft areas, such as windows, doors and strong heating vents or fans.
Tools and materials needed for installation: If local codes and ordinances permit, A.G.A. design-certified, flexible metal tubing is recommended for connecting this cooktop to the gas supply line. Do Not kink or damage the flexible tubing when moving the cooktop. A 3/8” (.95 cm) male pipe thread is needed for connection to pressure regulator female pipe threads. shutoff valve E The supply line shall be equipped with an approved shutoff valve.
Now start... With cooktop in kitchen. --..._ - grate q1 Remove shipping materials and tape from cooktop. Remove pressure regulator and hardware package from side of carton. burner 1 2. 1 Remove cooktop and burner grates package from shipping box. Remove plastic parts bag from inside cooktop. Remove parts from bag and line up next to your tools. Lift entire cooktop up from cutout when repositioning cooktop in countertop opening.
flexible connector I 3/W (0.95 cm) adabters manual shutoff valve All connections mounting holes holes C. Lift maintop slightly and release support rod. Pull maintop forward until hinges lock. Lower maintop. 3/W’ (0.95 cm) nipple 1 pressure regulator Electronic Ignition Initial lighting System - Cooktop burners use electronic igniters in place of standing pilots. When the cooktop control knob is turned to the “HI” position, the system creates a spark to light the burner.
Natural gas conversion L.P gas conversion Converting a qualified to L.P. gas should installer. be done by Converting to Natural gas should by a qualified installer. Fire Hazard Shut off gas supply line valve. Make all conversions before turning gas supply valve back on. Failure to follow these instructions can result in explosion, fire or other injury. J Natural Fire Hazard Shut off gas supply line valve. Make all conversions before turning gas supply valve back on.
If cooktop does not operate... l l l l If you need service... Check that the circuit breaker is not tripped or house fuse blown. Check that power supply cord is plugged into outlet. Check that the gas valve is turned to the “ON” position. A more detailed troubleshooting checklist is provided in the Use and Care Guide. * operating mstructlons and cleanmg If you need assistance...