Operation Manual

19
Electrical connection
Regulations require that the appliance be earthed.
Connection to the mains must be carried out by a qualified electrician in accordance with the
manufacturer's instructions and in compliance with local regulations.
The installer is responsible for connecting appliances correctly to the mains and for observing the safety
regulations.
The oven power cable must be long enough to connect the built-in appliance to the mains.
Observance of safety directives requires that a multi-pole switch with a minimum contact gap of 3mm
be used for the installation.
Do not use multiple plug adapters or extension leads.
After the oven has been installed, the electrical components must be inaccessible.
Connecting the oven to the power supply
Make sure that the voltage indicated on the rating plate is the same as the mains voltage. The rating
plate is on the front edge of the oven (visible when the door is open).
1. Remove the two fastening screws of the terminal box cover located on the bottom part of the oven's
rear covering.
2. Remove the cover to gain access to the terminal box and insert the power cable
(see table) through the opening located on the bottom of the oven.
3. Connect the cable to the terminal box, tighten the screws as far as they will go and secure it to the
cable fastener.
4. Put the cover back on by inserting the two blades in the slots and fasten it with the two screws.
Power supply cable table
N° of conductors Type of cable
1N+
~
H05 RR-F 3 X 4 mm²
2+
~
H05 RR-F 3 X 4 mm²
2N+
~
H05 RR-F 4 X 2.5 mm²
3N+ ~
H05 RR-F 5 X 1.5 mm²
3+ ~
H05 RR-F 4 X 2.5 mm²