Dimension Guide

®/™
© 2018 Whirlpool. All rights reserved. Printed in the U.S.A.
For 90 days from the date of original purchase, when this commercial
appliance is installed, maintained, and operated according to instructions
attached to or furnished with the product, Whirlpool Corporation
(hereafter “Whirlpool”) will pay for factory-specied replacement parts
and repair labor to correct defects in materials or workmanship that
existed when this commercial appliance was purchased. For the rst two
years from the date of purchase, when this major appliance is installed,
maintained, and operated according to the instructions attached to
or furnished with the product, Whirlpool will pay for factory-specied
replacement parts to correct defects in materials or workmanship that
existed when this commercial appliance was purchased.
See whirlpoolcommerciallaundry.com for warranty details.
WY180053 4/18
*Based on 2018 United States DOE J2 Testing with factory preset cycles.
**Use 4” (100mm) diameter rigid aluminum or galvanized steel duct. Never use plastic, non-metal, or combustible duct.
+It is recommended that a separate circuit serving only this washer / dryer be provided.
See Installation Guide for complete dimension details.
Commercial Combination Stack
Washer / Dryer
Specifications
Side View
Back View
MODEL
CET9000GQ
CET9100GQ
CGT9000GQ
CGT9100GQ
U.S. / Int’l U.S. / Int’l
Fuel Type
Electric Gas
WASHER SPECIFICATIONS
CAPACITY
Cylinder Volume — cu. ft. (liters) 3.10 ( 88) 3.10 ( 88)
Cylinder Diameter — in. (mm) 21.60 (547) 21.60 (547)
Cylinder Depth — in. (mm) 13.40 (340) 13.40 (340)
WATER INLET HOSE / DRAIN HOSE
Operating Pressure – psi (bar)
20 – 100 (1 – 8) 20 – 100 (1 – 8)
Inlet Hose Length — ft. (m)
4 (1.22) 4 (1.22)
Drain Hose Length — ft. (m) 6 (1.83) 6 (1.83)
APPROXIMATE WATER USAGE
Average Total Water Usage Per Cycle — gallons (liters)* 12.24 (46.33) 12.24 (46.33)
Average Hot Water Usage, Warm Water Cycle — gallons (liters) 1.5 (5.67) 1.5 (5.67)
Average Hot Water Usage, Hot Water Cycle — gallons (liters) 2.28 (8.63) 2.28 (8.63)
ELECTRICAL REQUIREMENTS
Voltage 120V N/A
Electrical Requirements / Frequency 60Hz N/A
Breaker / Fuse – amps 30 N/A
DIMENSIONS – DOOR OPENING – IN. (MM) 14.25 (362) 14.25 (362)
EXTRACT SPEED — MAX G-FORCE / MAX RPM
300/1,000 300/1,000
MOTOR SIZE — HP (KW)
1/2 (.37) 1/2 (.37)
INTEGRATED WATER FACTOR (IWF)*
4 4
MODIFIED ENERGY FACTOR (MEF
J2
)*
2.2 2.2
ADA-COMPLIANT Yes Yes
DRYER SPECIFICATIONS
CAPACITY
Cylinder Volume — cu. ft. (liters) 6.70 (190) 6.70 (190)
Cylinder Diameter – in. (mm) 26.3 (666.8) 26.3 (666.8)
Cylinder Depth – in. (mm) 20.4 (518.3) 20.4 (518.3 )
ELECTRICAL REQUIREMENTS
Voltage 240V 120V
Electrical Requirements / Frequency 60Hz 60Hz
Breaker / Fuse – amps
+
30 15
DIMENSIONS – DOOR OPENING – IN. (MM) 18.25 (464) 18.25 (464)
DRYER EXHAUST DUCT DIAMETER – IN. (MM)** 4 (100) 4 (100)
ELECTRIC HEATING ELEMENT (WATTS) 5,600
N/A
GAS RATING — BTU/HR. (KCAL/HR.)
N/A
22,000 (4,544)
GAS INLET SIZE
N/A
3/8 NPT
MOTOR SIZE – HP (KW) 1/3 (.25) 1/3 (.25)
MACHINE SPECIFICATIONS
DIMENSIONS
Width — in. (mm) 27 (686) 27 (686)
Depth — in. (mm) 29.50 (751) 29.50 (751)
Height — in. (mm) 74 (1,880) 74 (1,880)
CRATED DIMENSIONS
Crated Width — in. (mm) 29.25 (743) 29.25 (743)
Crated Depth — in. (mm) 34 (864) 34 (864)
Crated Height — in. (mm) 75.75 (1,924) 75.75 (1,924)
APPROXIMATE WEIGHT
Uncrated — lbs. (kg) 372 (169) 378 (171)
Crated — lbs. (kg) 383 (173) 389 (176 )
Coin Equipped
Card Ready & Non-Vend
2-YEAR LIMITED
PARTS ONLY
WARRANTY / 90-DAY LABOR
Dimensions are for planning purposes only. See specic instructions for proper installation. Because of
continuous product improvement, Whirlpool reserves the right to change specications without notice.