Service manual

4-5
REMOVING THE CONVECTION THERMOACTUATOR
AND THE WIDE INTERFACE BOARD
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
5. To remove the convection thermoactuator:
a) Disconnect the two wire connectors
from the terminals.
b) Remove the two screws and remove
the thermoactuator.
6. To remove the WIDE interface board:
a) Disconnect the two wire connectors at
P1 and U3.
b) Push and unlock the tab and remove the
WIDE interface board from its bracket.
P1
U3
Tab
WIDE Interface Board
1. Unplug oven or disconnect power.
2. Open the microwave oven door, remove
the two flat-head screws from the bottom
of the control panel frame, and remove the
frame.
Control Panel Frame Screws
3. Remove the four screws from the front
subpanel and remove the subpanel as-
s
embly.
4. Disconnect the P1 and P2 connectors from
the microwave and lower oven control board
connectors and set the panel assembly
aside.
Front Subpanel Screws
P2 P1 P2 P1
Lower Oven Board
MW Oven Board
Convection Thermoactuator
WIDE Interface Board
Wire Connectors
Thermoactuator Screws