Service manual

4-7
REMOVING THE MICROWAVE DOOR INTERLOCK
SWITCHES AND THE CAVITY LIGHT
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1. Unplug oven or disconnect power.
2. Open the microwave oven door, remove
the two flat-head screws from the bottom
of the control panel frame, and remove the
frame.
Control Panel Frame Screws
3. Remove the four screws from the front
subpanel and remove the subpanel as-
s
embly.
4. Disconnect the P1 and P2 connectors from
the microwave and lower oven control board
connectors and set the panel assembly
aside.
Front Subpanel Screws
P2 P1 P2 P1
Lower Oven Board
MW Oven Board
Sec. Interlock Sw.
Primary & Monitor
Interlock Switches
5. To remove the secondary interlock
switch:
a
) Remove the two mounting bracket
screws from the front of the switch
holder on the left front side of the MW
oven, and remove the holder.
b) Disconnect the blue (COM) and white
(N.O.) wires from the switch termi-
n
als.
c) Raise the locking tabs and pull the
switch off the pins and out of the switch
holder.
Cavity Light
Sec. Interlock Sw. Screws
Secondary Interlock Sw.
BU (COM)
WH (N.O.)
Continued on the next page.