Service manual

4-9
REMOVING THE MAGNETRON THERMOSTAT
AND THE MAGNETRON
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
4. To remove the magnetron thermostat:
a) Disconnect the two wire connectors
from the thermostat terminals.
b ) Remove the two screws from the ther-
m
ostat and remove the thermostat.
5. To remove the magnetron:
a) Remove the magnetron thermostat (see
step 4).
b) Remove the eight screws from the inner
cover and remove the cover.
Inner Cover Screws (3 of 8)
c) Remove the right screw from the mi-
crowave appliance manager board
bracket.
Top Cover
Screws (2 of 4)
1. Unplug oven or disconnect power.
2. Remove the oven from its mounting location
(see “Installation Informationin Section 2)
and pull it forward so that you can access
the top cover.
3. Remove the four screws from the top cover
and remove the cover.
Magnetron Thermostat
Screw (1 of 2)
Wire Connectors
Bracket Screw
Continued on the next page.
Magnetron & Magnetron Thermostat