Service manual

5-3
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
WARNING
MONITOR FUSE
Refer to page 4-6 for the procedure for access-
ing the monitor fuse.
1. Unplug oven or disconnect power.
2. Disconnect one of the wires from the fuse
holder terminals.
3.
Set the ohmmeter to the R x 1 scale.
4. Touch the ohmmeter test leads to the fuse
holder terminals. The meter should indicate
a closed circuit (0 Ω).
MICROWAVE DOOR
INTERLOCK SWITCHES
Refer to page 4-7 for the procedure for access-
ing the microwave door interlock switches.
1. Unplug oven or disconnect power.
2. Disconnect one of the wires from the door
interlock switch terminals.
3. Set the ohmmeter to the R x 1 scale.
4. Touch the ohmmeter test leads to the COM
and N.O. terminals of the door interlock
switch. The meter should indicate an open
circuit (infinite).
5. Press the actuator button on the interlock
switch. The meter should indicate a closed
circuit (0 Ω).
COM
N.O.