Service manual

5-12
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
WARNING
CONVECTION RING ELEMENT
Refer to page 4-32 for the procedure for ac-
cessing the convection ring element.
NOTE: The convection ring element will be
tested
at the appliance manager board (see
page 4-18).
1. Unplug oven or disconnect power.
2. Set the ohmmeter to the R x 1 scale.
3. Touch the ohmmeter test leads to wire con-
n
ectors T3-2 (YL) and T2-2 (R/W). The meter
should indicate between 33 and 37 Ω.
Lower Oven
Appliance Manager
T3
1 2 3 4 5
CONVECTION FAN MOTOR
Refer to page 4-32 for the procedure for ac-
cessing the convection fan motor.
NOTE: The convection fan motor will be tested
at the appliance manager board (see page
4-18).
1. Unplug oven or disconnect power.
2. Set the ohmmeter to the R x 1 scale.
3. Touch the ohmmeter test leads to wire
connector P8-3 (OR) and the neutral (WH)
stud on the AC terminal block. The meter
should indicate approximately 18 Ω.
1 2 3 4 5 6
Lower Oven
Appliance Manager
T2
2
P8