Service manual

6-6
FAILURE
(Leftmost
2 Clock
Digits)
ERROR
(Rightmost
2 Clock
Digits)
MESSAGE/DESCRIPTION
SUGGESTED CORRECTIVE ACTION PROCEDURE
F6
E1
E2
COOK oven OVER TEMPERATURE
CLEAN oven OVER TEMPERATURE
PROCEDURE:
Before proceeding, press OFF, OFF, START to enter the Diagnostic
mode.
A
. If oven is off, turn oven on and inspect all of the elements, convect ring, bake
and broil. Visually inspect all elements to ensure they are not operating.
B
. Unplug oven or disconnect
power. Wait 10 seconds.
C . Enter into Diagnostics
following steps 1 through 3 on from page 6-2.
D . P ress the B
AKE key to cycle the bake relay on and off as long as Diagnostics
mode is within the first 120 seconds of power up.
E
. If the bake relay does not cycle,
proceed to step F.
F. Unplug oven or disconnect power for 30 seconds.
G
. Plug in oven or reconnect power.
H
. Enter into Diagnostics
by pressing OFF, OFF, START. Press the BAKE key and
cycle
relay on and off.
If the bake relay does not cycle on and off, go to step O.
If the element does not cycle with the relay, go to step M.
If the element does cycle
on and off, go to step I.
I. P ress the BROIL key, while in Diagnostics mode, to cycle the broil relays.
Press
BROIL key one time for outer broil element. Ensur
e outer broil relay energizes by
inspecting the outer broil element. Press BROIL key again for inner broil element.
Ensure inner broil relay energizes by inspecting the inner broil element.
If broil relay does not turn on and off, go to step O.
If the element does not cycle with the relay, go to step M.
If the element does cycle
on and off, go to step J.
J. Press the CONVECT key, while in Diagnostics mode, to cycle the convect relay
on and off.
K
. If the convect
relay does not turn on and off, go to step O.
L. If the element does not cycle with the relay, go to step M.
M. Unplug oven or disconnect
power.
N. Check integrity of all harness wires and connections between the appliance
manager and the electrical elements. Ensure all wiring and connections between
the appliance manager and elements, and the appliance manager and user
interface are intact and properly seated and that no wires are shorted or
damaged.
O
. Unplug oven or disconnect
power.
P . Replace the appliance manager. Go to step S.
Q
. Replace user interface board. Go to step S.
R
. Replace the harness.
S
. Replace all parts and panels before operating.
T
. Plug in oven or reconnect power.
U
. Verify operation is normal. Press OFF, OFF, START
to reenter Diagnostic mode
and complete checks.
F6
E3
MINI OVEN/WARM DRAWER OVER
TEMPERATURE
PROCEDURE:
Oven is not equipped with this feature. If error occurs, before
proceeding press OFF, OFF, START enter into Diagnostics mode, then replace user
interface with correct control associated with this product.
FAILURE
(Leftmost
2 Clock
Digits)
ERROR
(Rightmost
2 Clock
Digits)
MESSAGE/DESCRIPTION
SUGGESTED CORRECTIVE ACTION PROCEDURE
F6
E4
USER INTERFACE/
APPLIANCE MANAGER MISMATCH
PROCEDURE:
Before proceeding, press OFF, OFF, START to enter the Diagnostic
mode.
A
. Unplug oven or disconnect
power. Wait for 10 seconds.
B. Plug in oven or reconnect power.
C
. Enter into Diagnostics mode by pressing OFF, OFF, START.
D
. Press BAKE. Ensure bake relay energizes by inspecting
bake element.
E. Press BROIL one time for outer broil element. Ensure outer broil relay energizes
by inspecting the outer broil element.
F
. Press BROIL again for inner broil element. Ensure inner broil relay energizes by
inspecting the inner broil element.
G
. Press SELF CLEAN to drive door latch to lock door. Press again to reset the door
latch to normal state.
H
. P ress COOK to activate
the low speed cooling fan. Press again for high speed.
I. If all functions are working, the AM and UI are properly working.
J
. Exit Diagnostics by pressing OFF.
K
. Press BAKE and ensure that bake relay energizes and the control enters the
bake preheat. Wait up to 60 seconds
to ensure error has been resolved. If error
returns, proceed to step L.
L
. Unplug oven or disconnect
power.
M. Remove covers for access to oven controls.
N
. Replace the appliance manager. Ensure all connections
are properly seated. Go
to step O.
O
. Replace all parts and panels before operating.
P
. Plug in oven or reconnect power.
Q
. Press BAKE
and ensure the bake relay energizes and the control enters into
bake/preheat. Wait up to 60 seconds to ensure error has been resolved.
If error returns, go to step R.
R
. Replace the user interface. Ensure all connections are properly seated. Go to
step S.
S
. Replace all parts and panels before operating.
T
. Plug in oven or reconnect power.
U
. Press BAKE
and ensure the bake relay energizes and the control enters into
bake/preheat. Wait up to 60 seconds to ensure error has been resolved.
F6
E5
NO CAVITY SIZE COMMAND
PROCEDURE:
Before proceeding, press OFF, OFF, START to enter Diagnostics
mode. Control should immediately power up in cavity size select
mode. Using key #6
(down) and key #3 (up) scroll through to locate the corresponding cavity size. Once
located, press the start key to accept the proper cavity size for the unit being
programmed. Control should reinitialize to cavity s
ize selected. If error returns at least
60 seconds after cavity size has been set, go to step A.
A
. Unplug oven or disconnect
power. Wait 10 seconds.
B. Plug in oven or reconnect power.
C
. Enter into Diagnostics mode by pressing OFF, OFF, START.
Press #6
(down) once main diagnostics
screen appears. Screen should identify cavity
size for unit being programmed. If this is incorrectly
shown, press CLOCK to
edit current programmed size. Press #6 (down) to locate the proper cavity size.
Once located, press S
TART to accept the new cavity size. Control will reset
and initialize
the new cavity size programmed. Wait for 60 seconds to ensure
error has been corrected.
If error is corrected, replace all parts and panels before operating.
If error returns, proceed to step D.
D
. Unplug oven or disconnect
power.
E. Replace user interface oven control ensuring all connections are properly seated
and go to step F.
F
. Replace all parts and panels before operating.
G
. Plug in oven or reconnect power.
H
. Control may power up in cavity size select mode. Set cavity size as outlined in
step C
by locating proper cavity size and pressing START once located.
I. Wait for at least 60 seconds
to ensure error has been corrected.