Installation guide

WARMINGDRAWERSAFETY
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING."
These words mean:
You can be killed or seriously injured if you don't immediately
follow instructions.
You can be killed or seriously injured if you don't follow
instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
INSTALLATIONREQUIREMENTS
O?,
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.
Tools needed
Phillips screwdriver
Hand or electric drill
1%" (3.5 cm) hole saw
Parts supplied
Four #8-18 x 3/8"screws
Check local codes. Check existing electrical supply. See
"Electrical Requirements."
It is recommended that all electrical connections be made by a
licensed, qualified electrical installer.
Make sure you have everything needed for correct installation. It is
the responsibility of the installer to comply with the installation
clearances specified in these instructions.
IMPORTANT: Observe all governing codes and ordinances.
Cutout dimensions that are shown must be used. Given
dimensions provide minimum clearance with warming drawer.
Recessed installation area must provide complete enclosure
around the recessed portion of the warming drawer.
Grounded electrical supply is required. See "Electrical
Requirements" section.
Electrical supply outlet should be located in the rear wall on
the upper right-hand side of the cutout or in an adjacent
cabinet. The outlet must be recessed. If the electrical outlet is
located in an adjacent cabinet, a 1%" (3.5 cm) minimum
diameter hole should have been drilled in the back of the
cutout or support surface to pass the power supply cord
through to the outlet.
Warming drawer support surface must be solid, level and flush
with bottom of cabinet cutout.
For best performance results make sure the warming drawer is
leveled before completing installation. There is no way to level the
warming drawer after it has been installed. If the installation is not
level, the door may slide open or not seal tightly, allowing heat to
escape.
Product Dimensions
_B
i
C
A. 29%4" (75.6 crn) overall width
B. 28_A'' (71.8 crn) recessed width
C. 9" (22.9 crn)