Installation guide

Wall ventingor recirculating venting:Go to step 2.
Reef=venting installation:The damper MUST fully open.
Checkthat damper blade @ is on top of tab ® and moves
freely. Note: if possibie, fit the damper assembly and vent
connector or transition piece together to check that the
damper opens fully before making final vent connection.
Insert damper assembly through cabinet opening ® so that
long tab ® slides under the raisededge of damper plate.
Use screw to attach short tab to damper piate and
microwave hood cabinet.
Align damper/vent connector with damper assembly on top
of microwave hood and attach. Install vent through vent
opening in upper cabinet.
Use caulking compound to seal roof opening around
exhaust cap.
lm
®
Salida de aire a tray,s de la pared o sin samidade aire
(recireulaciOn): vayaal Paso 2.
Jnstaiaei6n consalida de aire a tray,s del eiemerase: La
compuerta DEBEabrirse comptetamente. Verifique que Ia
hoja de Ia compuerta @ est6 sobre Ia IengOeta® y se pueda
mover iibremente. Nota: Si fuera posibb, unaei conjunto de
la compuerta y el conector deI conducto desaiida de aire o ia
pbza de transiciOn pare verificar si ia compuerta se abre
compietamente antes de hacer la conexiOnfinal del conducto
desalida de aire.
Inserte e! conjunto de ia compuerta a travOs de ia abertura
del gabinete © de manera que Ia IengOetaIarga @ se @slice
debajode! borde levantado de la placa de ta compuerta. Fije
la ]eng{Jetacorta a la placa de ]a compuerta con el tornillo de
roscado brillante que no se us6 para fijar la placa de la
compuerta.
Alinee ia compuerta/e! conector deI conducto de saiida de
aire con eI conjunto de Ia compuerta sobre Ia campana det
homo y fijeta. Instale el conducto de salida de aire a travOsde
la abertura desatida de aire dei gabinete superior.
Use masilIa de calafatearpara seller la abertura en el cielo
raso atrededor de la caperuzade saIidade aire.
CoiI power supply cord through clamp ®. Secure clamp to
cabinet side wall with dark colored screw.
EnrolIeet cabie de aiimentaciOnen Ia abrazadera®. Fijela
abrazaderaa la pared lateral del gabinete con el tornillo
oscuro.
18
Referto Owner's Manualor Useand CareGuidefor
instructions to assemblecharcoalfilters into your modei.
(Note: Dependingon model, charcoal filters may not be
included.)
Consulte en el Manual de! Propietarioo Ia Guiade Usey
Cuidado ias instrucciones para instalar ios fiitros de carbon
en su modeto.
(NOTA: Dependiendo det modelo, los filtros decarbon
puedenno estar incluidos.)
Referto OwneCsManuai or Useand CareGuidefor
instructions to assemblefilters into your model.
Consuite en el Manual del Propietario o ia Guiade Usoy
Cuidado las instrucciones para instalar los filtros en su
modelo.
Mug power cord into grounded outtet.
Reconnectpower supply.
m
EnchufeeI cable de alimentaciOnen et tomacorriente puesto a
tierra. Vuelnaa conector el suministrode energia.
Readthe Owner's Manual or Useand CareGuide, then
check the operation of microwave hood.
m
Leaei Manuai det Propietario o ia Guiade Usoy Cuidado,
luego verifique el funcionambnto de la campana de salida de
aire det homo de microondas.
19