Specifications

Sixth Sense Technology
6th Sense software makes an estimation of
the actual food temperature inside the
refrigerator and freezer compartment and
adjusts cooling to allow the food packages to
return their initial temperature faster during
pull down, door openings, or heavy food load.
6th Sense algorithm runs in both FC and RC
and each contains 3 routines: Trigger,
Package Estimator, and Defrost Manager.
Trigger routine is executed every 2.5 seconds while Package Estimator and
Defrost Manager are executed every 10 seconds. The trigger routine is divided
into two subroutines: door monitoring and temperature monitoring.
Trigger parameters and performance parameters reside in the UI board, the
actual 6
th
sense algorithm resides in Gemini Flash board.
Package Estimator routine computes an estimation of food in FC and RC
according to Thermistor reading and door status. Package estimator is run when
the User Interface sends the required parameters to Gemini flash and sets the
6th Sense Enable bit to true. If 6th Sense is needed, it will call for additional
cooling by turning on compressor, damper and evaporator fan.
Defrost manager is composed of two main states: Normal and 6th Sense.
When 6th Sense routine is active, defrost will be inhibited based on the control
parameters settings to allow food temperature recovery.
.
Introduction Specifications and Overview